查詢結果分析
相關文獻
- 食品工廠檢測仙人掌桿菌及金黃色葡萄球菌之能力評估
- 乳品中仙人掌桿菌、金黃色葡萄球菌及沙門氏桿菌污染之調查
- Bacterial Foodborne Outbreaks in Central Taiwan, 1991-2000
- Simultaneous Detection of Food Pathogens, Staphylococcus aureus, Salmonella Enterica, Bacillus cereus and Vibrio parahaemolyticus by Multiplex Real-Time Polymerase Chain Reaction
- 市售食品微生物之衛生品質調查
- 102年度金黃色葡萄球菌檢驗之能力試驗
- 臺灣常見之食品致病細菌
- 供膳人員糞便檢體中之金黃色葡萄球菌及仙人掌桿菌的帶菌率
- 比較直接接種與增菌後移種方法對糞便中四種食品中毒病原菌的檢出效能
- 化學試驗組參與ASTM能力試驗計劃結果評估
頁籤選單縮合
題 名 | 食品工廠檢測仙人掌桿菌及金黃色葡萄球菌之能力評估=Competency Assessment on Bacillus cereus and Staphylococcus aureus Enumerations of Food Manufactories in Taiwan |
---|---|
作 者 | 何秋燕; 陳禹心; 彭瑞森; | 書刊名 | 臺灣農業化學與食品科學 |
卷 期 | 48:5 2010.10[民99.10] |
頁 次 | 頁248-256 |
分類號 | 412.37 |
關鍵詞 | 仙人掌桿菌; 金黃色葡萄球菌; 能力試驗; Bacillus cereus; Staphylococcus aureus; Proficiency test; |
語 文 | 中文(Chinese) |
中文摘要 | 仙人掌桿菌 (Bacillus cereus) 和金黃色葡萄球菌 (Staphylococcus aureus) 是常見的食品中毒菌,本文針對國 內食品工廠的品管實驗室,以能力試驗 (proficiency test, PTest) 評估其對這兩種病原菌典型菌落判定計數的 檢測程序合適性。以選擇性培養基,進行仙人掌桿菌BA與BB兩個樣品及金黃色葡萄球菌SA、SB與SC三個 樣品的檢測。仙人掌桿菌的檢測結果,其實驗室內的檢測結果差異(|Zwi|)在1.76以下,由於BA與BB兩樣品 實為相同的樣品,顯示實驗室的重複性檢測結果為合適。但由各廠商間的檢測結果差異(Zbi),發現廠商編號 M11的檢測結果偏離標準,其Zbi為-5.99,由尤頓圖得知,該廠商的檢測程序出現系統性的誤差。對金黃色 葡萄球菌檢測PTest結果,發現廠商編號M17的廠商間檢測結果差異(Zbi)偏離標準,其Zbi為-3.69,尤頓圖亦 顯示該廠商的檢測結果出現系統性的誤差。經檢測程序分析,發現兩家廠商均於培養24小時後即判讀典型菌 落計數菌數,但典型菌落特徵需培養48小時才可完全顯現,因而造成低估菌數的現象。由能力試驗評估顯示 95%參與試驗的實驗室的自主檢測能力良好,但是對於仙人掌桿菌和金黃色葡萄球菌各有一家工廠因培養計 數時間未達48小時,造成低估菌數的現象,經能力試驗分析後,已更正其檢測的程序。 |
英文摘要 | Bacillus cereus (B. cereus) and Staphylococcus aureus (S. aureus) are both common food poisoning bacteria; hence this research looks into the procedures of how domestic food manufactories enumerate the typical colony counts of these two pathogenic bacteria. The proficiency test (PTest) was used to collect data on the accuracy of the manufactories’ detection procedures with the selective culture media. The food manufacturers which participated in the research were asked to perform tests on two B. cereus samples, BA and BB, and three S. aureus samples, SA, SB and SC. For both BA and BB, laboratory results via the PTest showed a within lab Z score (|Zwi|) of less than 1.76. Since BA and BB actually were the same samples, it indicated the appropriateness of the laboratory’s recurrent test results. However, the manufacturers’ between lab Z score (Zbi) showed manufacturer No. M11 exhibiting a deviation from the standard, with a -5.99 Zbi value. According to the Youden Plot, systematic errors occurred in that particular manufacturer’s testing results. For Staphylococcus aureus, the testing results showed that results from manufacturer No. M17 exhibited a -3.69 Zbi value. The Youden Plot also illustrated systematic errors occurred during the testing process for manufacturer No. M17. After thorough analysis, it was concluded that incubation time was the reason why the two manufacturers exhibited an underestimate result. Both conducted the discriminative readings on the typical bacterial colonies for counting bacterial populations after 24 hours incubation. However, the typical bacterial colony characteristics would not be fully exhibited until being cultured for 48 hours. The competency assessment indicated that 95% of the food manufacturers participating in the research exhibited an outstanding voluntary testing competency. As for the two manufacturers which underestimated the bacterial population by not extending the culture and counting time, their testing procedures were corrected after discussion. |
本系統中英文摘要資訊取自各篇刊載內容。