題 名 | 三單位固定式部份義齒於雷射熔接後邊緣密合度的變化=Marginal Accuracy of Three-unit Fixed Partial Denture by Laser Welding |
---|---|
作 者 | 何价惠; 蔡宗一; 王若松; | 書刊名 | 中華牙醫學雜誌 |
卷 期 | 18:2 1999.06[民88.06] |
頁 次 | 頁81-90 |
分類號 | 416.96 |
關鍵詞 | 雷射熔接; 邊緣密合度; 鑄造用金合金; 鈀銀合金; 鈦金屬; Laser welding; Marginal accuracy; Casting gold; Pd-ag alloy; Titanium; |
語 文 | 中文(Chinese) |
中文摘要 | 本實驗的目的在於探討以雷射熔接(laser welding)方法連接兩段分開來的三單位 固定式部分義齒後,其邊緣密合度的變化情形。使用三種牙科常用金屬:第三類鑄造用 金合金、鈀銀合金及鈦金屬。於適當的雷射條件下連接兩段分開來的金屬鑄造冠後,由 電腦影像處理系統測量整個�G復物在邊緣密合度的變化情形。邊緣縫隙的測量結果以兩 方面來討論。第一部份分為大臼齒及小臼齒,第二部份為遠離雷射熔接位置及靠近雷射 熔接位置。結果顯示,第三類鑄造用金合金,雷射熔接前後,邊緣縫隙的變化量,在大 臼齒部位為0.00 um,在小臼齒部位為3.24 um;在大臼齒部位與小臼齒部位的遠離雷射 熔接位罝為1.77 um,靠近雷射熔接位置為1.47 um。鈀銀合金依序分別為1.80 um, 1.44 um,2.46um,0.78um。鈦金屬則為2.15 um,0.31um,1.56um,3.40um。 統計結果顯示,除了第二類鑄造用金合金的小臼齒部份,在雷射熔接前後邊緣縫隙變化 量的成對母體平均數差異檢定,有統計學上的意義外,其餘不論是組間或組內的統計學 比較,都沒有明顯差異。由此顯示,雷射熔接技術雖會造成鑄造物在邊緣密合度上的改 變,但此變化程度不大。因此雷射熔接技術是一種可信賴的連接方法。 |
英文摘要 | The objective of this investigation was to determine the change of marginal accuracy of two separated three-unit fixed partial dentures after being joined using laser welding. We used three dental alloys (type Ⅲ casting gold alloy, Pd-Ag alloy, and pure titanium) to connect the two separated parent metals under appropriate laser welding conditions. Then, after connecting to a computer image processing system via CCD camera under a stereomicroscope, we measured the changes of the marginal accuracy of the whole prosthesis directly on the computer monitor. The results showed that with the type Ⅲ casting gold alloy, the changes of marginal accuracy after laser welding were 0.00 um in molar, 3.24 um in premolar and 1.77 um in the outer aspect of the welded joint, 1.47 um in the inner aspect of the welded joint. The Pd-Ag alloy were 1.8 um, 1.44 um, 2.46 um and 0.78 um, respectively, while they were 2.15 um, 0.31 um, 1.56um and 3.40 um, respectively for titanium. We used the one-way ANOVA and the paired t-test to analyze the data. The t-test was used to compare the data of molar-premolar and outer-inner aspect, between groups and within group variances. The t-test showed the change of marginal accuracy after laser welding in premolar using type Ⅲ casting gold alloy demonstrated statistical significance. For all others, there were no statistically significant differences in the change of marginal accuracy between groups or within groups. Through this investigation and analysis, we found that the laser welding, although having some effects, did not make a significant change in the marginal accuracy of castings. Therefore, laser welding is a reliable technique for casting connection. |
本系統中英文摘要資訊取自各篇刊載內容。