查詢結果分析
相關文獻
- Evaluation of Isotopic Analogs as Internal Standard for Quantitative Determination of Urinary 6-Acetylmorphine by Gas Chromatography/Mass Spectrometry
- 以氣相層析質譜方法及氘同位素藥物為內部標準品應用於定量尿液中安非他命之探討
- 替代燃料對汽柴油引擎性能、毒性、污染與噪音特性分析之研究
- 固相微量萃取法(SPME)在酒類揮發成份分析上之應用
- 液化石油氣汽車引擎性能、毒性、污染與噪音特性分析及預測模式建立之研究
- Preparative Isolation and Gas Chromatography-Mass Spectrometry Analysis of Triterpenoids in Kansui Radix
- Analysis, Formation and Inhibition of Cholesterol Oxidation Products in Foods: An Overview (Ⅱ)
- 以氣相層析質譜儀分析半導體業作業環境中丙酮、異丙醇及甲苯方法之建立
- Detection and Determination of Phenformin in Chinese Medicinal Capsules by GC-MS and HPLC
- 中藥摻加西藥成分檢驗研究之回顧與展望
頁籤選單縮合
題 名 | Evaluation of Isotopic Analogs as Internal Standard for Quantitative Determination of Urinary 6-Acetylmorphine by Gas Chromatography/Mass Spectrometry=以氣相層析質譜分析方法及氘同位素藥物為內部標準品應用於定量尿液中6-乙酼嗎啡之探討 |
---|---|
作 者 | 黃炳中; 連美華; 張柏林; | 書刊名 | 藥物食品分析 |
卷 期 | 6:1 1998.03[民87.03] |
頁 次 | 頁423-432 |
分類號 | 418.81 |
關鍵詞 | 6-乙酼嗎啡; 氣相層析質譜儀; 衍生化試劑; 6-acetylmorphine; GC/MS; Derivative; |
語 文 | 英文(English) |
中文摘要 | 本研究係探討以6-乙醯嗎啡(6AM)之氘同位素藥物6-AM-d�鬲陘熙□郱ヱ~及不同 衍生化試劑於氣相層析質譜儀分析尿液中 6AM 含量之適用性。 本研究所採用之衍生化試劑 為 trifluoroacetic anhydride (TFAA), pentafluoropropionic anhydride (PFPA) 及 hexamethyldisilazane (HMDS),分別進行衍生化後,探討全掃描質譜圖( Full Scan )及 選定離子監測( SIM )圖譜之離子碎片強度是否相互干擾, 並以迴歸分析其實際應用在定 量上之可行性。 研究結果顯示, 由全掃描質譜圖來分析, 6-TMS-AM 之質譜圖對於 6-TMS-AM-d �骨� m/z 287 處有些許干擾;但以 TFAA 及 PFPA 為衍生化劑時,並無明顯干 擾。 由選定離子監測質譜圖分析,6-AM-d �偵P 6-AM 經 TFAA 及 PFPA 衍生化後之選定離 子碎片相互干擾甚低;另,6-TMS-AM 之質譜圖對於 6-TMS-AM-d �骨� m/z 343 處有明顯干 擾。本研究再分別以 TFAA,HMDS 及 PFPA 為衍生化試劑,選擇適用之離子碎片為定量用離 子,進行迴歸分析,於 50,100,200,300,500,1000 ng/ml 濃度範圍內,具有良好的線 性關係。 因此以 TFAA,HMDS 及 PFPA 為衍生化試劑時,6-AM-d �偯野i供作氣相層析質譜 法分析尿液中 6- 乙醯嗎啡定量時的內部標準品。但以 HMDS 衍生化定量時,由於有明顯干 擾,應慎選適用之離子。 |
英文摘要 | This study examined the accessiility of using 6-acetylmorphine-d�� (6-AM-d �� ) as the internal standard and trifluoroacetic anhydride, pentafluoropropionic anhydride, and hexamethyl-disilazane as the derivatizing agents in the quantitative analysis of 6-acetylmorphine (6-AM) by full scan mode and selective ion monitoring (SIM) mode gas chromatography/mass spectrometry (GC/MS). In this study, fragments with minimal interference between the analyte and the internal standard were evaluated and selected for quantitative determination. Calibration curves and precision analyses were further performed using these selected ions. In the full scan mode, there was a certain interference between the mass spectra of trimethylsilyl derivative of 6-AM and those of 6-AM-d �� at some fragment ions. This requires that there be carefull selection of fragment ions for quantitative determination due to the potential cross-contribution and subsequent inaccurate results. On the other hand, 6-AM-d �� might be suitable as the internal standard in quantitative analysis of the trifluoroacetyl or pentafluoropropionyl derivative by GC/MS since the interference between the mass spectra of these derivatives of 6-AM and those of 6-AM-d ��,was minimal. In the SIM mode, results were similar with those of the full scan mode. The suitable fragments were thus selected for the calibration curve and precision analysis by SIM GC/MS. Excellent linearity was obtained over the concentration range of 50-1000 ng/ml of 6-AM for their TFA, PFP, and TMS derivatives. Good precision was also obtained from within-run and between-run CVs for 6-TFA-AM, 6-PFP-AM and 6-TMS-AM at a concentration of 200 ng/ml. 6-AM-d �� was demonstrated to be a suitable standard in quantitative analysis of TFA-, PFP-, or TMS- derived urinary 6-AM in SIM mode GC/MS analysis. |
本系統中英文摘要資訊取自各篇刊載內容。