查詢結果分析
相關文獻
- 放射治療用男性生殖器遮蔽物之研製與效能評估
- Elekta Synergy直線加速器kVCBCT與GE CT-Xim在體內輻射劑量之測量與研究
- 輻射鋼筋建物居民染色體變異分析評估生物劑量
- Postoperative Radiotherapy of Adult Supratentorial High-grade Astrocytoma
- Malignant Primary Extragonadal Germ Cell Tumors of Mediastinum--An Analysis of Clinical and Radiological Features in 15 Cases
- Radiation Therapy in Primary Central Nervous System Lymphoma
- Implications of a Failed Prospective Trial of Adjuvant Therapy after Radical Hysterectomy for Stage Ib-IIa Cervical Carcinoma with Pelvic Node Metastases
- 攝護腺癌之傳統放射線治療--長庚紀念醫院十四年之經驗
- Preoperative Radiotherapy in Patients with Lower Rectal Cancer:Results of Sphincter-Preservation, Treatment Outcome and Morbidities
- A Phase Ⅱ Study of Neoadjuvant Interferon Alfa-2B and Concurrent Interferon and Radiotherapy in Primary Untreated Undifferentiated Carcinoma of Nasopharynx
頁籤選單縮合
題 名 | Elekta Synergy直線加速器kVCBCT與GE CT-Xim在體內輻射劑量之測量與研究=The Dosimetry Comparison for Elekta Synergy Linear Accelerator kVCBCT vs GE CT-Xim |
---|---|
作 者 | 邱筱文; 柯天龍; 黃英明; 黃雯萱; | 書刊名 | 臺灣應用輻射與同位素雜誌 |
卷 期 | 13:3 2017.09[民106.09] |
頁 次 | 頁1497-1502 |
分類號 | 416.36 |
關鍵詞 | 放射治療; 劑量評估; Radiation therapy; kVCBCT; CT-Xim; Dosimetry; |
語 文 | 中文(Chinese) |
中文摘要 | 本研究將針對Elekta Synergy直線加速器的功能,kVCBCT在頭頸部、胸腔部及骨盆腔部擷取影像時,與原使用的GE CT-Xim在相同部位取像時,體內累積劑量的測量與比較。本研究以133顆熱發光劑量計分別置於人形假體頭、頸部、胸腔部、腹部及骨盆腔部切面內,分別用Synergy直線加速器執行以上部位的kVCBCT成像及GE CT Xim的切面掃描,掃描後的熱發光劑量計經計讀後,kVCBCT所累積的劑量比CT Xim低,在頭頸部平均約低了11.3倍(D_(CT-Xim)/D_(kVCBCT)=65.2mGy/5.8mGy);胸腔部及腹、骨盆腔平均約低了8.2倍(D_(CT-Xim)/D_(kVCBCT)=4.92mGy/0.6mGy)。因此臨床使用kVCBCT可大幅降低輻射劑量,尤其是頭頸部,對危急器官可達到劑量降低的目的。 |
英文摘要 | This study will focus on Elekta Synergy linear accelerator function, kVCBCT in the head and neck, chest department when capturing images, measuring and comparing the cumulative dose in vivo and pelvic portion of the original use of GE CT-Xim at the same site to capture images. In this study, 133 thermo-luminescence dosimeters were placed humanoid prosthetic head, inside the neck, chest , abdomen and pelvis department section, respectively, with the implementation of the above sites Synergy linear accelerator kVCBCT slice imaging and scanning operations of GE CT-Xim by thermo-luminescence dosimeters scanned by meter reading, kVCBCT cumulative doses lower than CT Xim, head and neck in an average of about 11.3 times lower (D_(CT-Xim)/D_(kVCBCT)=65.2mGy/5.8mGy), chest part and abdomen, pelvis average of about 8.2 times lower (D_(CT-Xim)/D_(kVCBCT)=4.92mGy/0.6mGy); therefore kVCBCT clinical use can significantly reduce the radiation dose , especially the head and neck , to the critical organ dose reduction. |