查詢結果分析
相關文獻
- 不同訓練環境高中籃球選手皮膚含水量與皮膚彈性之研究
- Central Retinal Vein Occlusion Associated with Cryofibrinogenemia in a Young Adult--Study of Skin Dynamic Capillaroscopy
- Intradermal Injection of Tramadol Has Local Anesthetic Effect: A Comparison with Lidocaine
- 新生兒皮膚調查--九九二位新生兒之分析
- 雙側卵巢Krukenberg腫瘤之皮膚轉移
- 原發性淋巴皮膚土壤絲菌病--星形土壤絲菌所致
- 一區域醫院門診1022個皮膚切片的分析
- 單一性肌肉纖維瘤
- Laryngeal Injury with Subcutaneous Emphysema: A Case Report
- Eosinophilic Fasciitis
頁籤選單縮合
題名 | 不同訓練環境高中籃球選手皮膚含水量與皮膚彈性之研究=A Study of Skin Water Content and Skin Elasticity among High School Basketball Players with Different Training Environment |
---|---|
作者 | 羅貫中; 成和正; 洪偉欽; 楊家豪; Lo, Guan-chung; Chen, Ho-cheng; Hong, Wei-chin; Yang, Chia-hau; |
期刊 | 嘉大體育健康休閒 |
出版日期 | 20160800 |
卷期 | 15:2 2016.08[民105.08] |
頁次 | 頁123-131 |
分類號 | 528.9012 |
語文 | chi |
關鍵詞 | 籃球選手; 皮膚; 室內室外; Basketball player; Skin; Indoor and outdoor; |
中文摘要 | 目的:探討不同訓練環境 (室內、戶外) 青少年籃球選手之皮膚含水量與皮膚彈性的差異性。方法:將28 名高中三年級籃球選手以立意取樣方式,分為室內訓練環境與戶外訓練環境2 組,每組各14 人,在室溫20-24℃,溼度50-60%的室內環境進行皮膚檢測。本研究採用儀器為德國製多功能皮膚檢測系統(Gutometer MPA580) 中之皮膚水分測定探頭 (Corneometer CM825),來測定皮膚含水量;以皮膚彈性測定探頭 (Cutometer MPA580 內建Viscoelasticity),來測定皮膚彈性。本研究統計方式以獨立樣本t-test,顯著水準訂為α=.05。結果:在不同訓練環境中,高中籃球選手之皮膚含水量並未達顯著;而皮膚彈性上有顯著差異。綜合上述,本研究之結論:高中籃球選手在不同訓練環境中,皮膚含水量並無顯著的差異,但皮膚彈性上有顯著差異。 |
英文摘要 | Skin isolates human body from external environment and protects us from harm. The essential factors of making skin work well are skin surface hydration, skin elasticity, transepidermal water loss and row of perspiration quantity. Skin is easy to expose to UV and injured when doing exercise training. Over a long period of time, UV will cause sunburn and even skin cancer. As so far, there are few studies of high school player's skin protection. To prevent high school players in different training space from injuring by exposure too much UV, The purpose of the research was to examine the difference of high school basketball players' skin water content and skin elasticity in different training space (outdoor and indoor) . The subjects of this research selected 14 high school basketball players training indoor and 14 high school basketball players training outdoor. The instrument we used was Corneometer CM825 (Gutometer MPA580). The data was analyzed by independent t test (α=.05). Result: The skin water content did not make much difference of high school basketball players, but it made obviously contrast of skin elasticity in different training environment. To tell from above, the conclusions of this study were as followed: In different training environment, the skin water content of the high school basketball players had no notable difference. The skin elasticity, had a significant difference between high school basketball players in different training environment. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。