查詢結果分析
相關文獻
- 嬰兒奶嘴材質試驗、溶出試驗及亞硝胺之測定
- 嬰兒奶嘴材質試驗、溶出試驗及亞硝胺之測定
- 蒸食饅頭用塑膠製品之衛生安全
- 發泡聚苯乙烯紙及發泡聚苯乙烯食品容器之衛生安全調查 dSurvey on Sanitary Status of Polystyrene Paper and Polystyrene Food Utensils
- 食品用紙製容器之衛生安全調查
- 101年度市售食品器具容器包裝衛生安全之監測
- A Review on Safety Inspection and Research of Plastic Food Packaging Materials in Taiwan
- 102年度市售塑膠奶瓶衛生安全之監測
- 103年度市售塑膠類食品器具容器包裝之衛生安全監測及其風險物質研究
- 橡膠中亞硝胺的形成(Ⅰ)--混合歷程的效應
頁籤選單縮合
題 名 | 嬰兒奶嘴材質試驗、溶出試驗及亞硝胺之測定=Survey on the Material Test, Leaching Test and the Contents of N-Nitrosamines in Baby Nipples |
---|---|
作 者 | 白美娟; 高雅敏; 張碧秋; 鄭秋真; 周薰修; | 書刊名 | 藥物食品檢驗局調查研究年報 |
卷 期 | 17 1999.10[民88.10] |
頁 次 | 頁285-292 |
分類號 | 412.25 |
關鍵詞 | 嬰兒奶嘴; 材質試驗; 溶出試驗; 亞硝胺; 氣相層析儀-熱能分析儀; Nipple; Material test; Leaching test; N-Nitrosamines; Gas chromatography-thermal energy analyzer; GC-TEA; |
語 文 | 中文(Chinese) |
中文摘要 | 為了解市售嬰兒奶嘴之衛生安全現況,於1994年7月至1995年6月間,共抽得嬰兒 奶嘴 31 件,依據行政院衛生署公告之標準與方法,分別進行材質試驗、溶出試驗及亞硝胺 含量之測定。結果顯示,在材質試驗方面,鉛、鎘兩項均未檢出,合乎衛生標準。在溶出試 驗方面,高錳酸鉀消耗量、重金屬、酚、甲醛、鋅及蒸發殘渣等六項亦均合乎衛生標準; 其 中高錳酸鉀消耗量為 0.3-9.5ppm,鋅為 0.03-0.4ppm,蒸發殘渣為 9-24ppm。 至於亞硝胺 含量之測定, 乃利用氣相層析儀 - 熱能分析儀 (gas chromatography-thermalenergyanalyzer, GC-TEA) 定量七種亞硝胺 (NDMA, NDEA,NDPA,NDBA,NPIP,NPYR,NMOR), 在 31 件嬰兒奶嘴中有 7 件檢出亞硝胺.檢出量為 1.1-84.8/7 ppb,其中 3 件不合格,不合格率為 9.7%; 若以奶嘴材質而分,20 件矽膠奶 嘴有 3 件不合格,不合格率為 15.0%, 而 11 件橡膠奶嘴則均未檢出; 若以奶嘴來源而分 ,17 件國產奶嘴有 2 件不合格,不合格率為 11.8%,14 件進口奶嘴有 1 件不合格,不合 格率為 7.1%。 |
英文摘要 | In order to investigate the sanitation and safety of commercial available baby nipples, from July 1994 to June 1995, a total of 31 samples that included 20 silicon and 11 rubber nipples were collected and examined. All tests followed the official methods and hygienic standards of Taiwan. In the material test, lead and cadmium were not detected in any of the 31 samples. In the leaching test, the consumption of potassium permanganate in all the samples was found to be 0.3- 9.5 ppm. The contents of zinc and evaporated residues were 0.03-0.4 ppm and 9- 24 ppm, respectively. Other tested items, such as phenol and formaldehyde, were found to be below the hygienic limit. In analysis of N-nitrosamines, NDMA, NDEA, NDPA, NDBA, NPIP, NPYR and NMOR were analyzed using a gas chromatography-thermal energy analyzer (GC-TEA). Of the 31 samples analyzed. N- nitrosamines were detected in 7 samples and the content ranged from 1.1-84.8 ppb. All of these 7 samples were made of silicone. Three samples (9.7%), including z domestic and 1 imported nipples, violated the tolerance level set by the Depart- ment of Health. |
本系統中英文摘要資訊取自各篇刊載內容。