查詢結果分析
來源資料
相關文獻
- A Measurement Algorithm for Evaluating Light Flicker Effect of Light Sources and a Design of a Portable Light Fliciker Meter
- 高雄地區九所高中職專二年級學生近視狀況與環境因素之研究
- 全身性紅斑狼瘡急性發作期導致暫時性高度近視及結膜水腫--病例報告
- Familial Correlation of the Optical Components between Myopic Children
- 高度近視之準分子雷射多層切割之術後評估
- 高度近親病人之閃爍融合閾值的變化
- A Review of Myopia Studies in Taiwan
- 近視及散光病人施行準分子雷射輔助層狀角膜重塑術後之不同角膜弧度值變化
- 臺灣近視手術治療的現況
- 接受屈光手術ALK剩餘近視度數以ALK手術再作修正之臨床結果
頁籤選單縮合
題 名 | 高度近親病人之閃爍融合閾值的變化=Change in the Modulation and Critical Flicker Frequency in High Myopia Patients |
---|---|
作 者 | 陳寶全; 翁林仲; 楊正烽; 施永豐; 林隆光; | 書刊名 | 中華民國眼科醫學會雜誌 |
卷 期 | 38:2 1999.06[民88.06] |
頁 次 | 頁208-214 |
分類號 | 416.765 |
關鍵詞 | 近視; Contrast sensitivity; Critical flicker frequency; Modulation transfer function; |
語 文 | 中文(Chinese) |
中文摘要 | 前言:我們發現在視神經炎病人「即使在恢復期」及青光眼病人會有視神經及 ganglion cell的傷害,而且在閃爍融合閾值(Critical Fhcker Frequency)(CFF)也會有 降低之情形。而在高度近視的患者也有視網膜退化的情形。所以本篇論文在研究及探討是 否高度近視病人有Modulation[%]及閃爍融合閾值(Critical Flicker Freque-ncy)(CFF) 的變化。我們希望針對高度近視之視網膜退化所影響的視覺功能做進一步探討,進而能早 期診斷,早期治療。 材料及方法:由眼科門診連續選取了84個高度近視而視力矯正至0.8以上患者,我們使 用Cyclus Flicker Fusion Meter 731(INTER-ZEAG AG,CH-8952 Schileren, Switzerland)來檢查這些病人。這臺機器不僅可以檢查各頻率之Modulation[%],更可記 錄他們的閃爍融合閾值(Critical FIicker Frequency)(CFF)。 結果:雖然每個病人在每次檢查之間會有變化,但這臺機器可以自動劃出各頻率間之 Modulation[%]的平順曲線,此曲線即稱為Modulation Transfer Function(MTF)。在高度 近視患者閃爍融合閾值為46.91±10.13 Hz,而正常對照組為52.96±3.90Hz(P=O.0003)。 我們可以發現高度近視患者閃爍融合閾值(Crit-ical Flicker Frequency)(CFF)的降低及 Modulation[%]的升高。 討論:高度近視會有視網膜退化之情形,根據本研究,其會有閃爍融合閾值(Critical Flicker Fusion)(CFF)降低及對比敏感度(con-trast sensitivity)降低之情形。將來我 們可以再加研究,以便利用其做為評估高度近視病人視網膜退化程度的指標。 |
英文摘要 | Purpose: We can find some optic nerve damage and ganglion cell damage in the optic neuritis and glaucoma patients, we also noted critical flicker frequency (CFF) decrease in these patients. Retinal degeneration is found in high myopia patient. Are there any changes in the modulation [%] and critical flicker frequency (CFF) in the high myopia patients? We want to use these visual function as indexes to evaluate the severity of high myopia retinopathy. Material and Method: Thirty-four patients of high myopia (more than 8D) were collected in our OPD. We use Cyclus Flicker Fusion Meter 731 (INTERZEAG AG, CH-8952 Schlieren, Switzerland) which can detect modulation [%] in all frequencies [Hz] and record their critical flicker frequency (CFF). Result: Although there are fluctuation between examinations, but fortunately, this machines can calculate the data automatically and plot a smooth curve for the relation of modulation [%] and frequencies [Hz]. There are statistical significance (P=0.0003) in critical flicker frequency between high myopic (46.91*10.13 Hz) and normal (52.96±3.90 Hz). We found there are decrease of critical flicker frequency (CFF) and increase of mnodulation[%] in all frequency in the high myopia patients. Discussion: There is retinal degeneration in high myopia patient. According to our finding, there are decrease of critical flicker frequency( CFF) and increase of modulation [%] in all frequency. Maybe we can use the critical flicker frequency(CFF) and modulation transfer function(MTF) as indexes to evaluate the severity of retinal degeneration in high myopia patients. |
本系統中英文摘要資訊取自各篇刊載內容。