頁籤選單縮合
題 名 | 空氣污染防治--火力發電廠硫氧化物篇=SOx Control in a Fossil Power Plant |
---|---|
作 者 | 蕭木村; | 書刊名 | 台電工程月刊 |
卷 期 | 609 1999.05[民88.05] |
頁 次 | 頁70-91 |
分類號 | 445.63 |
關鍵詞 | 逆流式噴霧塔; 順流式填充塔; 碟盤塔; 液氣比; 反應劑利用率; 固體滯留時間; 種晶; Counter-current flow spray tower; Co-current flow packed tower; Tray tower; Liquid-to-gas ratio; Reagent Utilizaion; Solids residence time; Seed-crystal; |
語 文 | 中文(Chinese) |
中文摘要 | 台灣電力公司核火工處負責籌建興達電廠三、四號機組的排煙脫硫系統,按照該 計劃規範中的要求,筆者概要描述了擬購置之排煙脫硫系統,包括對該系統製程的描述、質 量的平衡、設備的基本要求、以及一些設計因素的討論。 |
英文摘要 | Taiwan Power Company is undertaking the installation of flue gas desulfurization system for units 3& 4 at Hsin-Ta Power Station. Based on the requirement in the specification prepared for said project, the author tried to briefly describe the flue gas desulfurization system including description of the process of the system, mass balance, some basic design requirement of the equipment, and discussion of some design factors. |
本系統中英文摘要資訊取自各篇刊載內容。