頁籤選單縮合
題 名 | 談臺電諧波管制政策之我見=Comments on Taipower's Harmonic Regulation Policy |
---|---|
作 者 | 林昆平; 林明鋒; | 書刊名 | 台電工程月刊 |
卷 期 | 608 1999.04[民88.04] |
頁 次 | 頁20-29 |
分類號 | 448.115 |
關鍵詞 | 各次諧波電流失真; 綜合諧波電流失真; 系統諧振點; 責任分界點; 自動功因調整器; Harmonic current distortion; Dh; Total harmonic current distortion; THDi; System resonant point; Duty point; DP; Auto power factor regulator; APFR; |
語 文 | 中文(Chinese) |
中文摘要 | 近來諧波問題日益嚴重,台電特於82年頒佈諧波電流管制政策以期改善供電品質, 但執行至今,成果不甚理想。本文主要從一諧波案例分析過程,探討台電現行諧波管制策略 的得失,以作為再度修改政策時的參考。 |
英文摘要 | Due to being serious with harmonic, Taiwan power company has promulgated a decree for limiting harmonic current. But up to now, the effect was not remarkable. This topic takes an accident of power cut due to harmonic as an example and criticizes advantage and shortcoming of the harmonic regulating policy. At last, we gave some suggestion for the future. |
本系統中英文摘要資訊取自各篇刊載內容。