題 名 | 稻穀預冷作業之研究=The Study on Paddy Precooling Process |
---|---|
作 者 | 盛中德; 周子豪; | 書刊名 | 農林學報 |
卷 期 | 47:4 1998.12[民87.12] |
頁 次 | 頁1-12 |
分類號 | 434.119 |
關鍵詞 | 稻殼; 預冷; 能源效益; Paddy; Precooling; Energy efficiency; |
語 文 | 中文(Chinese) |
中文摘要 | 本研究以三個筒倉進行稻穀的預冷測試,以評估其預冷作業時之作業性能、能 源效益。系統在入筒倉之溫度12.14℃、相對濕度90.92%、稻穀含水率15%,在三筒倉滿 倉時(共33噸),得其作業之能源效益約為45.3%,在試驗時間1000min結束後,筒倉內的 溫差為1.4-2.4℃、其所引發的空氣自然對流稻穀水分轉移的效果非常有限。 |
英文摘要 | The experiment was conducted to test paddy precooling process in three round bins. The purpose of this study is to evaluate the performance and energy efficiency of the paddy precooling system. The inlet air temperature was 12-14℃, relative humidity was 90-92%, and moisture content of the test paddv was 15%. The capacity of each bin is 11 tons of psddy. The test were conducted while three bins were fully filled. The evergy efficiency was calculated to be 45.3% after the experiment had been processed for 1000 minutes. After the test, the temperature variations within bins were 1.4-2.4 ℃. Due to there small temperature variations the effects of natural air converction and moisture migration of paddy would be very limited and negligible. |