查詢結果分析
來源資料
相關文獻
- 建築新趨勢--具輻射空調系統之模組式手術房
- 生長鵝之生長性狀及血液成分變化
- 土壤缺水與農作物植體溫度之關係
- Removal of Renal Cell Carcinoma Extending into Supradiaphragmatic Inferior Vena Cava Using Cardiopulmonary Bypass with Deep Hypothermic Circulatory Arrest--A Report of 2 Cases
- 低體溫
- 體溫與麻醉
- 到院時死亡病患的中心體溫、動脈血pH值與心臟停止期間之關聯
- Inadvertent Hypothermia Causes Pulseless Electrical Activity in a Patient during Cervical Spine Surgery--A Case Report
- 某教學醫院婦產科門診婦女對測量基礎體溫之認知及其相關探討
- Unexpected Delivery before Arrival at Hospital: An Observation of 18 Cases
頁籤選單縮合
題 名 | 建築新趨勢--具輻射空調系統之模組式手術房=The Trend of Building: A Modular Operating Room with Radiant Cooling System |
---|---|
作 者 | 林宗茂; 陳明晃; 陳家盈; | 書刊名 | 醫務管理期刊 |
卷 期 | 24:4 2023.12[民112.12] |
頁 次 | 頁408-422 |
分類號 | 416.31 |
關鍵詞 | 手術房; 輻射空調; 模組式設計; 體溫; 電燒煙霧; Operating room; Radiant cooling system; Modular design; Body temperature; Electrosurgical smoke; |
語 文 | 中文(Chinese) |
DOI | 10.6174/JHM.202312_24(4).408 |
中文摘要 | 目的:比較新式、傳統手術房在空氣品質及使用者舒適感受上的差異。 方法:個案醫院以新式手術房為實驗組,相同條件之傳統手術房為對照組,收集室 內壓差、落塵量、落下菌量、風速、換氣次數、風量、溫度、濕度、可視化煙霧流 向及 40 位人員使用感受以比較兩組的差異。 結果:兩組之室內壓差、落塵量、落下菌量、換氣次數、溫度及濕度測試結果皆合 乎國家規範;實驗組的風速、風量明顯、煙霧上揚程度低於對照組。九成以上人員 對兩組的溫度及整齊度感到舒適,半數人員對兩組的煙霧異味感到不適。在空調氣 壓感受上實驗組比對照組佳,但可用空間感受比對照組差。 結論:新式手術房能降低電燒煙霧、噪音,增加可利用空間,但實際數據與感受有 落差,瞭解落差能提供給其他醫院作未來手術房建造之參考。 |
英文摘要 | Objectives: To compare the difference of the air quality and users’ perception of comfort between a modern operating room and a typical operating room. Methods: The modern operating room was the experimental group and the typical operating room similar with the modern operating room was the control group. The overall air conditions including the pressure difference, indoor fallout, off the bacteria, air exchange per hour, air temperature, humidity, air velocity, volume flow rate, and flow visualization in selected buildings were collected. A questionnaire survey was administered to 40 workers in both rooms for users’ perception of comfort. Results: In both groups, the pressure difference, indoor fallout, off the bacteria, air exchange per hour, air temperature, and humidity enable to comply with the Taiwan Green Productivity Foundation guidelines for operating room. The air velocity and the volume flow rate in the experimental group were lower than those in the control group. Results of the 40 participants, more than 90% experienced comfortable with temperature, more than 50% experienced uncomfortable with electrosurgical smoke from both rooms. In the experimental group, staffs experienced comfortable with air pressure more than those in the control group and experienced comfortable with available space lower than those in the control group. Conclusion: This modern building design will be to reduce the harmful effects of electrosurgical smoke and noise, and to increase available space. Knowing the difference between facts and feeling can contribute to the development of operating room. |
本系統中英文摘要資訊取自各篇刊載內容。