題 名 | 雙能量電腦斷層對肝臟脂肪含量的定量分析:假體研究=Quantification of Liver Fat Content Using Dual-Energy CT: A Phantom Study |
---|---|
作 者 | 蔡長諭; 李榮輝; 楊志明; 林正欣; 趙世裕; 周瑞祥; | 書刊名 | 中華放射線技術學雜誌 |
卷 期 | 40:1 2016.03[民105.03] |
頁 次 | 頁21-26 |
分類號 | 416.246 |
關鍵詞 | 雙能量電腦斷層掃描; 肝臟脂肪含量; 衰減曲線; Dual-energy computed tomography; Liver fat content; Attenuation curve; |
語 文 | 中文(Chinese) |
中文摘要 | 本研究的目的是研究雙能電腦斷層(dual energy computed tomography, DECT)對肝臟脂肪含量(liver fat content, LFC)的定量分析。本研究使用兩個假體:豬肝臟/脂肪和葡萄糖/丁醇的混合物,使用80 kV/ Sn140kV(stannum, Sn)和100 kV/ Sn140 kV 雙能掃描含有已知濃度的肝臟脂肪混合物(0%、10%、20%、30%、40%、100%),從數據得到衰減曲線,用於呈現不同程度的LFC在不同能量的衰減。從數據中分析,豬肝臟/脂肪混合物無法得到LFC曲線,原因為豬肝並非活體肝臟,脂肪並無法經由肝動脈與門靜脈進入肝臟,外加脂肪並無法使脂肪進入肝臟細胞,故脂肪量的增加CT量測的HU(Hounsfield units)值並無下降,這是豬肝臟/脂肪混合物不均勻所導致。結果雙能模式(80 kV/ Sn140 kV Sn 和100 kV/ Sn140 kV)對已知脂肪濃度的葡萄糖假體與量測的HU 值之間有高度的相關性(R^2>0.99,P<0.005)。使用DECT 數據可獲得衰減曲線並鑑別各種程度的LFC,我們認為DECT 應可做為臨床上定量肝臟脂肪的有效工具。 |
英文摘要 | The purpose of this study was to examine dual-energy computed tomography (DECT) for liver fat content (LFC) quantitative analysis. Two phantoms were used in this study: one was made up by porcine liver and fat; the other one was glucose solution mixed with butanol. Tubes containing mixtures with known fat concentrations were scanned on a DECT scanner using dual-energy scanning protocols (80 kV/Sn140 kV (stannum, Sn) and 100 kV/Sn140 kV). LFC was calculated from DECT data and compared with the known LFC (0%、10%、20%、30%、40%、100%). Attenuation curves obtained from DECT were used to describe attenuations of various degrees of LFC at different energies. The phantom of porcine liver/fat mixtures was not used for liver fat quantification because porcine liver is not living liver and fat cannot enter into porcine liver via the hepatic artery and portal vein. The increase of fat content did not show a decline of Hounsfield units (HU). This may be due to inhomogeneity in porcine liver and fat mixtures. The results show a correlation between DECT measurements and known LFC (R^2>0.99, P<0.005). Attenuation curves obtained from DECT data can be used for discriminating various degrees of LFC. DECT will be a reliable tool for liver fat quantification. |