查詢結果分析
來源資料
相關文獻
- Volume Illumination for Novel Micro PIV Measurement Technique
- 超微量雷射時間解析螢光分析法及非理想配比氧化鈾之氧鈾比值測定
- 雷射螢光偵測技術之建立及超微量分析應用
- 同步輻射X光奈米探針技術應用於奈米級別材料之螢光光譜與吸收分析技術
- 巴金森氏病患之吞嚥障礙及電視螢光錄影檢查
- 厭氧流體化床之生物膜顆粒層次模型及代謝活性試驗
- 合金鐵化學成份X-射線螢光分析法之建立
- 鋼鋁片鍍層與化成塗膜表面分析技術之應用
- The Regulatory Role of Plasma Membrane Proton-Pumping ATPase in Salt Tolerance of Soybean Plant Growing Under the Salt-Stress Condition
- A Measurement Algorithm for Evaluating Light Flicker Effect of Light Sources and a Design of a Portable Light Fliciker Meter
頁籤選單縮合
| 題 名 | Volume Illumination for Novel Micro PIV Measurement Technique=體積照亮式新式微質點速度影像量測技術 |
|---|---|
| 作 者 | 王明文; | 書刊名 | 亞東學報 |
| 卷 期 | 29 2009.06[民98.06] |
| 頁 次 | 頁1-8 |
| 分類號 | 440.12 |
| 關鍵詞 | 高頻率微質點速度影像量測法; 為流體裝置; 螢光; 時間解析; High frequency MPIV; Microfluidic device; Fluorescence; Time resolution; |
| 語 文 | 英文(English) |
| 中文摘要 | 摘要 微質點速度影像量測技術(MPIV)已經被廣泛的應用在微流體裝置中流場的速度量測上,為了能夠輕易且有 效的找出微流體裝置之中流場的暫態現象,有別傳統螢光量測演算法,本研究建置ㄧ個結合高速攝影技術、長 焦距顯微影像系統、高功率光放射二極體照明並以非螢光反置影像為演算法的高頻率微質點速度影像量測技術 (HFMPIV),其量測平面景深係以體積照亮所形成的直接光學景深加以之計算,同時定義有效的對比值將離開量 測光學景深未聚焦之粒子影像去除以降低量測信噪比,本方法在微流體裝置量測上將可以達到125s 時間解析 以及2.2×2.2m2 的空間解析,實驗結果顯示以高頻率微質點速度影像量測技術(HFMPIV)所得量測值與數值模擬 所得結果相當吻合,因此採用高頻微質點速度影像量測法進行微流體裝置中流場的速度量測,將能在不採用螢 光技巧的情況下獲得更短的量測時間解析。 |
| 英文摘要 | Abstract The micro particle image velocimetry (MPIV) technique has been widely adopted for the measurements of velocity field in microfluidic devices. To simply the investigation of the transient phenomena in a usual biological microfluidic device, this study, a novel high frequency MPIV technique without fluorescence, was developed by combining a high-speed CMOS camera, a long working distance zoom microscope, a high power LED along with reversed image algorithm. The depth of the measurement plane is defined by the focusing characteristics of the probing optics through volume illumination. With efficacious contrast base, the unfocused particle images, which are out of the measurement plane, create background noise that decreases the single-to-noise ratio of the particle image fields. The velocity fields of fluid in the micro device were visualized for a time resolution of 125s and a spatial resolution of 2.2×2.2m2. The result shows that the numerical predictions are very similar to the measurement of high frequency MPIV inside the micro flow device. Consequently, by using the novel MPIV technique, the time resolution can be abbreviated and the tracing particles require no decorating with fluorescing. |
本系統中英文摘要資訊取自各篇刊載內容。