查詢結果分析
相關文獻
- Spectrophotometric and Atomic Absorption Spectrometric Determination of Cephalexin and Cephradine in Dosage Forms
- Spectrophotometric Methods for Determination of Ritodrine in Bulk and in Pharmaceutical Dosage Forms
- 以近紅外線分光光度計偵測整粒稻穀脂肪酸度含量
- 纖維事故原因解析--機械分析Ⅲ: 紫外線可視分光光度計
- 以手提式近紅外線分光光度計測定稻米蛋白質及直鏈澱粉含量
- 以手提式近紅外線分光光度計非破壞性偵測梨果酸度
- 空氣中氮氧化物與二氧化氮之個人濃度值調查
- 以手提式近紅外線分光光度計非破壞性偵測蘋果內部品質
- 以分光光度計快速檢定油溶性抗氧化劑之抗氧化活性
- Comparison of ICG Finger Monitor System with Conventional Blood Sampling ICG Clearance Test in Patients with Acute Severe Hepatitis
頁籤選單縮合
題 名 | Spectrophotometric Methods for Determination of Ritodrine in Bulk and in Pharmaceutical Dosage Forms=以分光光度計法檢測散裝及藥品賦形劑中的Ritodrine |
---|---|
作 者 | El-Ghaffar, Mohamed Abd; Elsherbiny, Dina; El-Wasseef, Dalia; El-Ashry, Saadia; | 書刊名 | 藥物食品分析 |
卷 期 | 16:2 2008.04[民97.04] |
頁 次 | 頁26-35+105 |
分類號 | 415.53 |
關鍵詞 | 分光光度計; 劑形; NBD-Cl; 1,10-phenanthroline; Folin-Ciocalteu; Ritdorine HC1; Spectrophotometry; Dosage forms; |
語 文 | 英文(English) |
中文摘要 | 三種簡單、靈敏的分光光度計法於本文中被論述,用以檢測純態或劑形中的ritodrine hydrochloride(RTH)。第一種方法是根據4-chloro-7-nitrobenzo-2-oxa-1,3-diazole(NBD-C1)在pH 8.0的硼酸緩衝溶液產生黃色產物反應,其檢測波長爲392 nm。第二種及第三種方法是根據RTH分別與1,10-phenanthroline或Folin-Ciocalteu試劑發生氧化作用而產生紅色或藍色色原,其檢測波長分別爲510及760nm。此三種方法的最低檢測值分別爲0.1、0.05及0.14μg/mL,符合比爾定律的濃度範圍分別爲2-16、0.2-2及0.8-12μg/mL。影響有色物質形成與穩定的不同實驗參數已被詳加研究及最適化。不同外來物質及致敏物質對於三種方法成色之影響亦被研究。這些提出的方法已成功地應用在劑形中RTH的檢測。所得到的平均回收率(%)分別爲99.73±0.72、99.88±1.2及99.97±0.42。所得結果進行統計確效,並與參考方法所得之結果比較。另外,反應機構的資料亦被提出。 |
英文摘要 | Three simple and sensitive spectrophotometric methods are described for determination of ritodrine hydrochloride (RTH) either in pure form or dosage forms. The first method was based on the reaction with 4-chloro-7-nitrobenzo-2-oxa-1, 3-diazole (NBD-Cl) in borate buffer of pH 8.0 producing a yellow colored product measured at 392 nm. The second and third methods were based on RTH oxidation with either 1, 10-phenanthroline or Folin-Ciocalteu reagents producing red and blue chromogens which were measured at 510 and 760 nm, respectively. Beer's law was obeyed in the ranges of, 2-16, 0.2-2, 0.8-12 μg/mL with the minimum detectable values of 0.1, 0.05, 0.14 μg/mL for the three methods, respectively. Different experimental parameters affecting the development and stability of colored products were carefully studied and optimized. The effect of different foreign matters and sensitizers on the color development in the three proposed methods was also studied. The proposed methods were successfully applied to the determination of RTH in its dosage forms. The obtained percentage recoveries were 99.73±0.72, 99.88±1.2, 99.97±0.42 for the three proposed methods, respectively. The obtained results were statistically validated and compared with those obtained with a reference method. Proposals of the reactions mechanisms were presented. |
本系統中英文摘要資訊取自各篇刊載內容。