查詢結果分析
相關文獻
- Determination of Benazepril HCl and Hydrochlorothiazide in Pharmaceutical Preparations Using UV-Visible Spectrophotometry and Genetic Multivariate Calibration Methods
- 線性軸幅路網接駁系統最適整合區位、路線與排班模式之研究
- Genetic Algorithm Approach for Designing Fir Hilbert Transformers and Differentiators
- 以類神經網路與遺傳演算法解決系統可用度分派問題
- 自我調適的動態排程系統--限制排程、模糊理論和遺傳演算法的應用
- 用無母數的網路學習於臺股認購權證的定價
- 應用遺傳演算法優選大埔水庫排砂操作規線
- 手寫數字辨識模式之建立--結合遺傳演算法與類神經網路
- A Genetic Algorithm for Tuning Reliable Fuzzy System
- 以模糊理論和遺傳演算法為基礎的中文文件自動分類之研究
頁籤選單縮合
題 名 | Determination of Benazepril HCl and Hydrochlorothiazide in Pharmaceutical Preparations Using UV-Visible Spectrophotometry and Genetic Multivariate Calibration Methods=利用紫外光--可見光分光光度計及遺傳多變量校正法檢測製藥中Benazepril HCl與Hydrochlorothiazide之含量 |
---|---|
作 者 | Özdemir, Durmus; Dinc, Erdal; | 書刊名 | 藥物食品分析 |
卷 期 | 13:4 2005.12[民94.12] |
頁 次 | 頁301-311+393 |
分類號 | 412.36 |
關鍵詞 | 紫外光--可見光分光光度計; 多變量校正法; 遺傳演算法; 遺傳迴歸; UV-visible spectrophotometry; Multivariate calibration; Genetic algorithms; Genetic regression; |
語 文 | 英文(English) |
中文摘要 | 利用紫外光-可見光分光光度計、傳統最小平方法(GLS)與三組依據多變量校正法之遺傳演算法(GA)於多重檢測藥錠中benazepril及hydrochlorothiazide之技術已被論證。這三組遺傳多變量校正法包括遺傳傳統最小平方法(GcLS)、遺傳反最小平方法(GILS)及遺傳迴歸法。此資料庫包含下列樣品之紫外光光譜:28件benazepril(12~36 μg/mL)與hydrochlorothiazide(10~22 μg/mL)合成混合物及16件包含上述兩種成分之錠劑。光譜涵蓋範圍介於210~360 nm,間距為0.1 nm。許多校正模式即是以前述幾種方法建立而成。對所有的遺傳演算法,合成資料之均方根誤差校正(RMSEc)與均方根誤差確效(RMSEV)介於0.19~0.34 μg/mL。錠劑預測值之均方根誤差介於0.04~0.20 mg/tablets。選定波長下,針對每種成分之遺傳演算法比較亦被探討。 |
英文摘要 | Simultaneous determination of binary mixtures of benazepril and hydrochlorothiazide in pharmaceutical tablets using UV-visible spectrophotometry, classical least squares (CLS) and three genetic algorithms (GA) based multivariate calibration methods was demonstrated. The three genetic multivariate calibration methods are Genetic Classical Least Squares (GCLS), Genetic Inverse Least Squares (GILS) and Genetic Regression (GR). The sample data set contains the UV- spectra of 28 synthetic mixtures of benazepril (12~36 µg/mL) and hydrochlorothiazide (10~22 µg/mL) and 16 tablets containing both compounds. The spectra cover the range from 210 to 360 nm in 0.1 nm intervals. Several calibration models were built with the four methods. The root mean square error of calibration (RMSEC) and validation (RMSEV) for the synthetic data were in the range of 0.19 and 0.34 µg/mL for all the genetic algorithm based methods. The root mean square error of Prediction (RMSEP) values for the tablets were in the range of 0.04~0.20 mg/tablets. A comparison of genetic algorithm selected wavelengths for each component was also included. |
本系統中英文摘要資訊取自各篇刊載內容。