查詢結果分析
相關文獻
- Reproducibility of Peripapillary Retinal Nerve Fiber Layer and Macular Retinal Thickness Measurements Using Optical Coherence Tomography
- The Repeatability of Retinal Nerve Fiber Layer and Macular Thickness Measurements before and after Pupillary Dilation Using Optical Coherence Tomography
- Indocyanine Green Angiographic Features in Idiopathic Subfoveal Choroidal Neovascularization
- 老年性黃斑部病變之境界不明脈絡膜新生血管的灌流變化
- 玻璃體黃斑部牽扯症引發之黃斑部網膜剝離--病例報告
- 黃斑部的老化變性
- 使用雷射掃瞄式偏極計測量正常人視網膜神經纖維層厚度與它的再現性
- 玻璃體內注入空氣對黃斑部圓孔性網膜剝離之治療
- 染料雷射對增齡性黃斑部變性症之治療
- 網膜色素變性症之黃斑部病變研究
頁籤選單縮合
題名 | Reproducibility of Peripapillary Retinal Nerve Fiber Layer and Macular Retinal Thickness Measurements Using Optical Coherence Tomography=用光學同軸眼底斷層掃描儀測量視網膜神經纖維層及黃斑部視網膜厚度測量值的再現性 |
---|---|
作者姓名(中文) | 徐聖曜; 童逸楨; 許明木; 蔡榮坤; | 書刊名 | The Kaohsiung Journal of Medical Sciences |
卷期 | 22:9 民95.09 |
頁次 | 頁447-451 |
分類號 | 416.746 |
關鍵詞 | 黃斑部; 光學同軸眼底斷層掃描儀; 瞳孔散大; 視網膜神經纖維層; Macula; Optical coherence tomography; Reproducibility; Retinal nerve fiber layer; |
語文 | 英文(English) |
中文摘要 | 探討用光學同軸眼底斷層掃描儀測量正常眼視神經乳頭周圍視網膜神經纖維層及黃斑部視網膜厚度的測量值,並評估測量值在不同檢查人員間的再現性。每位正常受檢者任選一眼,由三位具經驗的檢查者用光學同軸眼底斷層掃描儀測量受檢眼視網膜神經纖維層及黃斑部視網膜厚度,並分析比較平均厚度值及三位檢查者檢查結果的差異性。研究中 39 位受檢者共 39 眼,受檢者 24 位女性,15 位男性,平均年齡 30.4 歲。檢查前瞳孔散大後的平均瞳孔直徑為 7.4 公厘。比較瞳孔散大後的厚度測量值,無論視神經乳頭周圍視網膜神經纖維層或黃斑部視網膜厚度,在三位具經驗檢查者間,並無顯著差異。用光學同軸眼底斷層掃描儀來測量正常眼視神經乳頭周圍視網膜神經纖維層及黃斑部視網膜厚度,在檢查者之間其測量值有好的再現性。 |
英文摘要 | We investigated the interoperator reproducibility of peripapillary retinal nerve fiber layer (RNFL) and macular retinal thickness measurements using optical coherence tomography (OCT) in healthy Taiwanese eyes. In this study, OCT-3 was used by three trained and experienced operators to measure peripapillary RNFL and macular retinal thickness in a randomly chosen single eye from each normal subject. Mean thickness levels and the differences in thickness measurements among the three operators were calculated and compared. The eyes of 39 subjects (24 females and 15 males) were enrolled. The mean age of the subjects was 30.4 ± 16.1 years (range, 11-46 years). The mean pupil diameter after pupillary dilation was 7.4 ± 0.6mm (range, 6-9mm). Comparing peripapillary RNFL and macular retinal thickness measurements after pupillary dilation, there were no significant differences in: superior, inferior, temporal, and nasal peripapillary areas; 6 mm total macular volume and foveal thickness; and 1, 3 and 6 mm perifoveal areas among the three operators. In this study, OCT thickness measurements showed good interoperator reproducibility among three trained and experienced operators. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。