查詢結果分析
相關文獻
- Mass Transfer from Solid Wall into Gas-Liquid Slug Flow Fluid in Small Diameter Tube
- Distribution and Mass Transfer of Phase Transfer Catalytic Intermediate in Two-Phase System
- Dynamic Model for Mass Transfer and Reaction in Liquid/Liquid Phase Transfer Catalysis with Internal Circulation within Dispersed Droplets
- Mass Transfer of a Forced Two Phase Flow on Rotating-Disk Electrode
- Natural Diffusion and Iontophoretic Delivery of Insulin in New-Designed Diffusion Cell
- Correction-Factor Analysis of Membrane Extraction in Flat-Plate Modules
- Two-Dimensional Current Distribution, Mass Transfer, and Metal Recovery in Packed Bed Electrodes
- Mass Transfer of Phenol Extraction Between Two Phases in a Constant Interfacial Area Cell and Stirring Tank
- Ozone Mass Transfer with Combined Effects of Ozone Decomposition and Reaction with Pollutants in a Semibatch Stirred Vessel
- 氣體擴散實驗的理論解析
頁籤選單縮合
題 名 | Mass Transfer from Solid Wall into Gas-Liquid Slug Flow Fluid in Small Diameter Tube=小管徑管中管壁與氣液兩相流體之質量傳送 |
---|---|
作 者 | 鄭東文; 張明仁; 詹凱雯; | 書刊名 | Journal of the Chinese Institute of Chemical Engineers |
卷 期 | 35:4 2004.07[民93.07] |
頁 次 | 頁477-483 |
分類號 | 460.02 |
關鍵詞 | 水動力學; 氣塊長度; 兩相流體; 質量傳送; 氣體流速; Two-phase flow; Mass transfer; Hydrodynamics; Gas slug velocity; |
語 文 | 英文(English) |
中文摘要 | 本文中探討在不同液體與氣體流速下尿素管壁溶解進入氣液兩相流體之質量傳送,並以相同管徑之透明管觀察其氣液兩相流動之流態。實驗觀察顯示在本實驗操作條件下,空塔液體流速與空塔氣體流速皆介於0.05至0.20 m/s,6 mm管徑中之氣液兩相流態是為塊狀流動,且氣塊長度隨氣體流速之增大而增長。實驗結果也顯示在氣液兩相流動中之質量傳送明顯高於單一液相中之結果。本文指出在氣液兩相系統中,液體流速固定下之質傳送正比於通氣比,而質傳係數與氣塊流速為二次函數關係。 |
英文摘要 | The mass transfer rate of urea from a solid wall into a gas-liquid two-phase flow fluid was investigated under various liquid and gas velocities. The two-phase flow pattern in a small diameter tube was also visualized by using a transparent tube. Experimental observation showed that the two-phase flow pattern in a 6 mm diameter tube was slug flow under the experimental flow condition; i.e. , both the superficial liquid velocity and superficial gas velocity were varied from 0.05 to 0.20 m/s. The length of the gas slug increased with the increase in the gas velocity. Experimental results also show that the mass transfer rate under two-phase flow operation was significantly higher than that under single liquid-phase operation. In the two-phase system, the mass transfer coefficient was proportional to the gas injection ratio at a specified liquid velocity. A quadric relationship between the mass transfer coefficient and the gas slug velocity is proposed in this work. |