題 名 | Vaccine Storage Practices in Primary Care Physicians' Offices in Taiwan=臺灣省預防接種合約醫院診所疫苗冷藏管理之調查 |
---|---|
作 者 | 白秀華; 葛應欽; | 書刊名 | The Kaohsiung Journal of Medical Sciences |
卷 期 | 15:5 1999.05[民88.05] |
頁 次 | 頁274-279 |
分類號 | 418.293 |
關鍵詞 | 臺灣; 疫苗; 冷藏; 疫苗管理; Vaccine; Vaccine storage; Cold chain survey; |
語 文 | 英文(English) |
中文摘要 | 為評估臺灣省預防接種合約醫院診所疫苗冷藏管理情形,於民國83年,自臺灣省21個縣市744家合約醫院診所中隨機抽樣63家醫院診所進行疫苗管理之實地訪視並測量冷藏疫苗冰箱之中心溫度,結果大部份之冷藏疫苗冰箱(93.7%)除存放疫苗外,尚存放其他物品,63家診所之存放疫苗冰箱中47.6%有擺置溫度計,46.0%之診所有記錄疫苗冷藏冰箱溫度,39.7%設有不斷電系統;40家疫苗管理者(63.5%)指出每年至少有一次停電之經驗;在調查的所有冷藏疫苗之冰箱皆是家用式的,沒有疫苗冷藏安全區的規劃;測量冷藏疫苗之冰箱溫度發現有22%(14/63)之冰箱冷藏室溫度超過8℃,76.3%(45/59)的冰箱扇門及73.7%(28/38)的冷凍室是無法達到疫苗冷藏(8℃)及冷凍溫度(-10℃)之要求,為了增進疫苗之冷藏管理,除了加強疫苗管理者有關疫苗之冷藏管理教育外,冷藏疫苗之冰箱及電力設備之改善亦有其必要性。 |
英文摘要 | To assess vaccine storage practices in Taiwan's clinics, an evaluation was made to determine whether they follow the relevant guidelines. A cross sectional study was carried out in March 1994, in which sixty-three clinics were selected at random from the 744 clinics in the twenty-one counties of Taiwan. Vaccine storage practices were inspected and the temperature of the central core of refrigerators used by these clinics for vaccine storage was measured. Of the 63 clinics, the majority (93.7%) stored articles other than vaccines in their vaccine refrigerators. Thirty clinics (47.6%) placed simple thermometers in their refrigerators; twenty-nine clinics (46.0%) used recording thermometers to produce temperature charts; and 25 clinics (39.7%) equipped their refrigerators with UPS (uninterruptible power system). Forty (63.5%) of 63 vaccine coordinators who were interviewed indicated at least one power failure per year. All refrigerators used for vaccine storage were of the domestic type without “safe zone” gauges. We discovered inappropriately high temperatures (>8 ℃) in 22% (14/63) of all refrigerators. Most refrigerator doors (76.3%, 45/59) or freezing rooms (73.7%, 28/38) were not maintained at a temperature required for storing vaccine. Coordinators should be carefully trained and refrigeration and electrical facilities be reassessed to improve vaccine storage in primary care physicians' offices. |