查詢結果分析
相關文獻
- Assessment of the Pericardia of Four Mammalian Species Fixed with an Epoxy Compound as Pericardial Heterografts
- Primary Pericardial Mesothelioma with Cardiac Tamponade and Distant Metastasis: Case Report
- Tuberculous Pericardial Effusion with Intrapericardial Echogenic Masses-- A Case Report
- Sudden Death Shortly after Successful Pericardiocentesis in Cardiac Tamponade Complicating in Aortic Dissection--A Case Report
- Ultrasonographic Demonstration of Intrapericardial Fibrous Layers in Tuberculous Pericarditis: Report of a Case
- 急性心包膜炎
- Comparison between Subxiphoid Approach and Left Thoracotomy in Surgical Treatment of Malignant Pericardial Effusion--The Experience of Taipei Veterans General Hospital
- Constrictive Pericarditis in Patients with Tuberculous Pericarditis
- Idiopathic Constrictive Pericarditis Mimicking a Right Ventricular Tumor--A Case Report
- 飛行中駕駛員猝死案例報告--主動脈剝離破裂
頁籤選單縮合
題 名 | Assessment of the Pericardia of Four Mammalian Species Fixed with an Epoxy Compound as Pericardial Heterografts=以環氧化物交聯處理不同哺乳類動物心包膜做為心血管補綴片的評估 |
---|---|
作 者 | 陳俊男; 吳慶強; 蔡承致; 宋信文; 張燕; | 書刊名 | Journal of the Chinese Institute of Chemical Engineers |
卷 期 | 28:6 1997.11[民86.11] |
頁 次 | 頁389-398 |
分類號 | 410.1644 |
關鍵詞 | 環氧化物交聯處理; 哺乳類動物; 心包膜; 心血管補綴片; Mammalian pericardium; Prosthesis; Epoxy compound; Wettability; Collagenase degradation; Mechanical strength; |
語 文 | 英文(English) |
中文摘要 | 哺乳類動物的心包膜,經交聯劑化學修飾後,常被用來做為心血管補綴片或人工心瓣膜的葉瓣。本研究比較了牛、羊、和狗四種不同哺乳類動物心包膜,經環氧化物交聯處理後的熱穩定性、機械強度、親疏水性、表面張力以及抵抗膠原酵素分解的能力等。藉此選擇一較適當的動物心包膜,以做為心血管補綴片或人工心瓣膜的材料來源。實驗結果顯示,以環氧化物交聯處理後的各式動物心包膜的熱穩定性、機械強度、親疏水性、表面張力以及抵抗膠原酵素分解的能力等皆相似。然而經環氧化物交聯處理後的牛心包膜在酵素分解前後的機械強度,皆較其他動物心包膜來得強。因此,臨床上若需使用機械強度較強的生物補綴片時,可以選擇牛心包膜做為其原料來源。 |
英文摘要 | Pericardia from varying mammalian species, chemically modified with a crosslinking reagent, have been use din the cardiovascular surgery as a biological patch or in the construction of heart valve prosthesis. The study was to compare the thermal stability, mechanical strength, wettability, surface tension, and resistance against collagenase degradation of the pericardia from calves, sheep, pigs, and dogs fixed with an epoxy compound. The aim was to expose an appropriate raw material to develop epoxy-fixed pericardial heterografts as alternatives to the glutaraldehyde-fxied prostheses for clinical applications. It was found that the thermal stability, wettability, surface tension, and resistance againse collagenase degradation of the pericardia from four species. Both before and after chemical modification, were comparable. However, the bovine pericardium appeared to have a better mechanical strength than the other societies. Therefore, if mechanical strength is an issue to be taken into account for assessing the performance of pericardial heterografts, the bovine pericardium seems to be the choice of raw material for constructing the prostheses. |