查詢結果分析
相關文獻
- The Correlation between Ultrasound-Detected Renal Parenchymal Thickness and Isotope-Detected Individual Renal Function
- Nephrosonographic Measurement on Renal Function Evaluation in Canine Surgically Induced Unilateral Hydronephrosis
- The Effect of Changes in the Internal Structure of a Schooling Fish on the Estimation Efficiency by Acoustic Methods
- The Use of Stationary Hydroacoustic Transducer to Study Diel and Seasonal Influences on the Distribution of Fish School in Water Adjacent to the Cooling Water Intake of Nuclear Power Plant III
- Detection of Renal Allograft Dysfunction with Color Doppler Flow Ultrasound
- Transcatheter Closure of Atrial Septal Defect Guided by On-Line Transesophageal Echocardiography
- Pelvic Abscess after Ultrasound-Guided Aspiration of Endometrioma: A Case Report
- Color Doppler Ultrasound Velocimetry of Internal Carotid Arteries in Normal Pregnancies
- Intraluminal Mucin Pool in Mucinous Gastric Adenocarcinoma: A Case Report
- Morbidity with Contemporary Transrectal Biopsy of the Prostate
頁籤選單縮合
題 名 | The Correlation between Ultrasound-Detected Renal Parenchymal Thickness and Isotope-Detected Individual Renal Function=超音波測量腎實質厚度與同位素測量單側腎功能的相關性 |
---|---|
作 者 | 周以和; 陳明潭; 黃俊雄; | 書刊名 | The Kaohsiung Journal of Medical Sciences |
卷 期 | 13:11 1997.11[民86.11] |
頁 次 | 頁682-684 |
分類號 | 416.273 |
關鍵詞 | 超音波; 腎實質厚度; 同位素測量; 腎功能; Renal parenchymal thickness; Renal scan; |
語 文 | 英文(English) |
中文摘要 | 超音波檢查是評估腎臟大小和腎實質厚度之簡單易操作方法。本研究目的在探討以超音波測量腎實質厚度與□Tc.DTPA同位素測量個別腎功能之相關性。10位男性,20位女性,共60個腎臟,以上述方法分別測量其腎實質厚度與腎功能,結果顯示兩者之相關性低,相關係數為0.1。但如比較每人兩側腎臟實質厚度差別與兩側腎臟功能差別,則相關係數可提高到0.67。本文結論認為以超音波測量任一腎臟之腎實質厚度並不適宜推測該腎之腎功能。但在同一人身上,以兩側腎臟之厚度差別來推測兩側腎臟之功能差別則較可信賴。 |
英文摘要 | Ultrasound has been used as a convenient examination method to obtain an estimate of the kidney size and parenchymal thickness. The aim of this study was to determine the relationship between the renal parenchymal thickness and Individual renal function. Renal ultrasonography to determine parenchymas thickness and 99mTc-DTPA renal scan to detect Individual renal function were carried out on 30 patients. The statistic analysts showed poor correlation between these two factors. The correlation coefficients Is 0.1 only. However, the correlation coefficients of the difference of bilateral renal parenchymas thickness and the difference of bilateral renal function In the same patient Is much higher (r =0.67). So, It Is unreliable to predict the random single renal function based on parenchymas thickness only. However, In the same patient, It Is sometimes worthwhile to differentiate bilateral renal function based on the difference of renal parenchymal thickness between the two kidneys. |