查詢結果分析
來源資料
相關文獻
- Solid-phase Extraction and High Performance Liquid Chromatographic Determination of Steroids Adulterated in Traditional Chinese Medicines
- Solid-phase Extraction and High-performance Liquid Chromatographic Analysis of Prednisone Adulterated in a Foreign Herbal Medicine
- 以高效液相層析法定量農產品中比多農殘留量
- Determination of Butocarboxim Residue in Agricultural Products by HPLC with Post-Column Derivatization System
- Determination of Amitraz Residue in Fruits by High Performance Liquid Chromatography
- 利用毛細管電泳定量中藥製劑成分
- 中藥製劑摻加Nifedipine之高效液相層析定量方法之應用
- 以高效液相層析儀及固相萃取方法分析蜜餞中人工甘味劑--糖精
- 固相萃取法與中藥製劑檢驗
- 高效液相層析儀檢驗法與化學滴定法及光度分析檢測法在磺胺劑類及類固醇賀爾蒙製劑之檢定比較試驗
頁籤選單縮合
題 名 | Solid-phase Extraction and High Performance Liquid Chromatographic Determination of Steroids Adulterated in Traditional Chinese Medicines=中藥製劑中摻加類固醇之固相萃取與高效液相層析研究 |
---|---|
作 者 | 顧祐瑞; 溫國慶; 何禮剛; 張永勳; | 書刊名 | 藥物食品分析 |
卷 期 | 7:2 1999.06[民88.06] |
頁 次 | 頁123-130 |
分類號 | 413.95 |
關鍵詞 | 類固醇; 固相萃取; 高效液相層析; 中藥製劑; 中藥摻加西藥之檢驗; HPLC; Steroids; Solid-phase extraction; Traditional Chinese medicine; Adulterant; |
語 文 | 英文(English) |
中文摘要 | 本研究以矽膠固相萃取法萃取摻加於中藥製劑中之八種類固醇betamethasone、 cortisone acetate、dexamethasone、hydrocortisone acetate、methylprednisolone、 prednisolone、prednisone及triamcinolone,再以高效液相層析法作定量分析比較,評估 個別之回收率。本實驗採用逆相層析管柱,沖提液為乙□與水(3:7),檢測波長為240nm,內 部標準品為fludrocortisone acetate作分析。八種類固醇檢量線之相關係數(r)為0.9983 至0.9996,均呈現良好線性關係。八種類固醇之同日間及異日間試驗之相對標準差,分別為 0.7-4.1%及1.0-4.4%,顯示再現性佳。固相萃取條件之探討包括萃取溶媒之組成、中藥製萃 取液之濃度及不同廠牌之固相萃取管等,均加以比較以建立最佳之萃取條件。 |
英文摘要 | A systematic evaluation and comparison of the recoveries of eight steroids from spiked traditional Chinese medicine (TCM) extract using silica gel solid-phase extraction (SPE) are reported. The eight steroids, betamethasone, cortisone acetate, dexamethasone, hydrocortisone acetate, methylprednisolone, prednisolone, prednisone and triamcinolone, adulterated in TCM were assayed simultaneously by high performance liquid chromatography on a reverse phase column. This chromatographic method was carried out using isocratic elution with acetonitrile and water (3:7). Fludrocortisone acetate was used as an internal standard and detection was at 240 nm. Calibration curves of the eight adulterants were constructed in the range 6- 96 μg/mL. Their correlation coefficients ranged from 0.9983 to 0.9996. The relative standard deviations of the eight steroids for intraday and interday analyses were 0.7-4.1% and 1.04.4%, respectively. Optimized experimental conditions including solvent composition, TCM extract concentration and different brands of SPE cartridge were also investigated. |
本系統中英文摘要資訊取自各篇刊載內容。