查詢結果分析
來源資料
頁籤選單縮合
| 題 名 | Forced Aeration of Rice in Warehouse=強制通風降低貯穀溫度之效果 |
|---|---|
| 作 者 | 盧福明; 陳必超; | 書刊名 | 農業工程學報 |
| 卷 期 | 34:2 1988.06[民77.06] |
| 頁 次 | 頁27-36 |
| 分類號 | 434.252 |
| 關鍵詞 | 通風; 貯穀; 溫度; |
| 語 文 | 英文(English) |
| 中文摘要 | 本文探討強制式通風作業降低貯穀溫度之效果,並應用複迴歸分析法探討影響穀物通風之因素。 |
| 英文摘要 | Aeration experiments were carried out in a concrete warehouse with a storage volume of 29 x 11.6 x 6 cubic meters, loaded with 1123 tons of rough rice. The analysis is based on the storage phenonmenon during summer aeration under subtropical weather in Taiwan. Stepwise regression was used for multiple linear regression analysis of the controlling factors on aeration. |
本系統中英文摘要資訊取自各篇刊載內容。