| 題 名 | Evaluation Clinical Application of Laboratory and Two Point-of-Care Analysers in HbA1c Measurement and Hemoglobin Variants=評估糖化血色素及變異血色素在實驗室與2臺POCT儀器之臨床上應用 |
|---|---|
| 作 者 | 胡耀峰; 黃翠蓮; | 書刊名 | Journal of Biomedical & Laboratory Sciences |
| 卷 期 | 34:4 2022.12[民111.12] |
| 頁 次 | 頁159-166 |
| 分類號 | 415.668 |
| 關鍵詞 | 糖尿病; 糖化血色素; 變異血色素; 糖尿病管理; 血糖控制; Diabetes mellitus; DM; Hemoglobin A₁c; HbA₁c; Hb variants; Diabetes management; Glycemic control; |
| 語 文 | 英文(English) |
| 中文摘要 | 目的 : 使用大實驗室 Sebia Capillarys3 分析儀,與 Abbort Afinion AS10 和 Siemens DCA Vantage 分析儀 在床旁檢測中的結果進行比較,以測量正常和變異的 HbA1c 之差異。 材料和方法 : 使用 EDTA 的全血檢體去執行親和力、免疫及電泳法分析。 結果 : 採集 132 檢體樣本經 Sebia Capillarys3 與 Afinion 和 DCA Vantage 的檢測 HbA1c 均顯示出良好 的 相 關 性 , 其 數 值 分 別 為 0.96 (Afinion 和 Sebia Capillarys3) 和 0.95 (DCA Vantage 和 Sebia Capillarys3)。在所有分析變異血紅素的樣本中,其包括 HbE、Hb G-新竹、Hb G-台中、α-地中海型貧血、 Hb-高雄、Hb J-Meinung 和 HbF 或其他 Hb 變異。 在有 48 名變異血色素的檢體中,顯示 Afinion 和 DCA Vantage 與 Sebia Capillarys3 的相關性分別為 0.84 和 0.87。最後,在 Bland-Altman 圖的 95%信賴區間 中,以 Sebia Capillarys3 當標準時呈現出 Afinion AS100 比 DCA Vantage 較低的偏差。 結論 : 兩種 POCT 分析法對實驗室標準法有極高的相關性,因此可廣泛應用於血糖控制檢測甚至醫生的 糖尿病管理中,並且減少因變異血色素可能影響 HbA1c 檢測數值方法以提高實驗室人員的局限性。 |
| 英文摘要 | Aim: To use Sebia Capillarys3 analyser of the laboratory and compared the result that Abbort Afinion AS100 and Siemens DCA Vantage analysers at point-of-care testing to measure HbA1c differences in normal hemoglobin and Hb variants. Materials and Methods: Directly tested ethylenediaminetetraacetic acid-containing venous whole blood and used the affinity, immuno-assay and electrophoresis of three analysers. Results: All 132 samples of HbA1c measurement by Sebia Capillarys3 showed good correlation with the result of Afinion and DCA Vantage, which was 0.96 (Afinion and Sebia Capillarys3) and 0.95 (DCA Vantage and Sebia Capillarys3). In all samples contained Hb variants, they were divided into heterozygotic HbE, Hb G-Hsin Chu, Hb G-Taichung, α-thalassemia, Hb Kaohsiungth, Hb J-Meinung and HbF or other Hb variants, respectively. Among forty-eight subjects were Hb variants, indicated that the correlation of Afinion and DCA Vantage to Sebia Capillarys3 was 0.84 and 0.87, respectively. Finally, regardless of Bland-Altman plot of the range of 95% limits of agreement revealed the low bias in Afinion AS100 than DCA Vantage versus SC3. Conclusion: Both POCT analysers revealed higher relative to SC3 reference method, so it could be widely used in glycemic control even to diabetes management for doctor and reduced the impact of Hb variants that might affect the numerical method of HbA1c inspection to increase the limitations of laboratory personnel. |