查詢結果分析
相關文獻
- 降低早產兒裝置鼻式連續性氣道正壓呼吸器導致鼻黏膜出血之專案
- 一位經產婦努力成為早產兒母親的經驗
- The Use of Prophylactic Intravenous Immunoglobulin Therapy in Very Low Birthweight Infants
- 極低出生體重早產兒造成腦性麻痺的危險因子之探討
- Home Oxygen Therapy for Chronic Lung Disease in Very Low-Birth-Weight Infants
- Optimal Timing of Retina Examinations for Premature Infants
- 早產兒父母的調適過程及其護理
- 早產兒父母支持團體推展方案--Stetler研究應用模式
- 極度早產兒的體內含鐵量過高會增加早產兒視網膜病變的危險性
- Heparin與早產兒腦室出血的危險性
頁籤選單縮合
題名 | 降低早產兒裝置鼻式連續性氣道正壓呼吸器導致鼻黏膜出血之專案=The Improvement Program to Minimize Nasal Bleeding Caused by Nasal Continuous Positive Airway Pressure (NCPAP) Treatment in Preterm Infants |
---|---|
作 者 | 譚靖馨; 邱曉彤; | 書刊名 | 長庚護理 |
卷期 | 29:4=104 2018.12[民107.12] |
頁次 | 頁542-555 |
分類號 | 419.75 |
關鍵詞 | 早產兒; 鼻式連續性氣道正壓呼吸器; 鼻黏膜出血; Preterm infant; Nasal continuous positive airway pressure ventilator; Nasal bleeding; |
語文 | 中文(Chinese) |
中文摘要 | 早產兒使用鼻式連續性氣道正壓呼吸器來促進肺泡擴張是常用的呼吸治療方式,而鼻黏膜出血為最常見的合併症。本單位於2014/1/1~8/1發生中度鼻黏膜出血發生率高達60%,因此引發改善專案之動機,經現況分析後歸納問題為:護理人員缺乏早產兒裝置NCPAP的相關照護知識、未制定NCPAP裝置流程圖、稽核制度及相關在職教育。本專案的目的為降低鼻黏膜出血發生率,提升護理人員照護能力,解決策略為重新更新NCPAP照護標準作業流程及制定NCPAP裝置流程圖、安排在職教育課程、定期執行品管監測、製作抽痰壓力提醒卡及人工皮剪裁範例、鼻導管型號選擇圖表,並重新製作固定呼吸管路帽帶,推行改善後鼻黏膜出血發生率降由60%降至15%,大幅提升病人的照護品質,於護理業務方面建議將來能有固定人員定期執行品管監測,並納入年度計畫重要指標內。 |
英文摘要 | Nasal Continuous Positive Airway Pressure (NCPAP) Therapy is a common treatment to for patients with breathing problems. In the case of preterm infants, NCPAP is often used to keep the alveoli open and expand the lung's surface area for ventilation. During NCPAP treatment, the complication of nasal bleeding is commonly seen. In the period between January 1, 2014 and August 1, 2014, we observed that more than 60% of the infants suffering from nasal bleeding as a consequence of NCPAP treatment. Such high percentage motivated us to find the solution to minimize the risk of nasal bleeding with NCPAP treatment. After further analysis, we concluded several factors contributing to the high nasal bleeding implication rate, including the lack of the proper training for the use of NCPAP in preterm infants, the lack of correct understanding and awareness of the implication of NCPAP treatment, the lack of a flow chart for NCPAP therapy, and the lack of an audit system to monitor the treatment process. To solve the above problems, several measures were undertaken, including updating the standard procedure of NCPAP treatment, establishing a correct NCPAP flow chart, arranging training courses, and monitoring the quality of the treatment and service. After implementation of the measures, the nasal bleeding rate after NCPAP treatment has significant decreased from 60% to 13%. We would highly recommend frequent and constant audits to improve the service and treatment quality. It is also important to include the audit as one of the key elements in the annual review. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。