題 名 | Improvement of Microcalcification Visualization Using Dual-Energy Digital Mammography: Impact on Different Breast Thicknesses and Tissue Components=利用雙能數位乳房攝影儀器改善微鈣化的可見度:針對不同之乳房厚度與組織成分的影響 |
---|---|
作 者 | 翁珮珮; 聶伊辛; 蔡佳容; 呂坤木; 蔡裕豐; | 書刊名 | 臺灣應用輻射與同位素雜誌 |
卷 期 | 11:1 2015.03[民104.03] |
頁 次 | 頁1021-1028 |
分類號 | 416.226 |
關鍵詞 | 微鈣化檢測; 數位乳房攝影; 雙能量影像; Microcalcification detection; Digital mammography imaging; Dual-energy imaging; |
語 文 | 英文(English) |
中文摘要 | 微鈣化是乳腺癌的早期指標之一,在早期階段偵測決定性的作用是在減少乳腺癌死亡率。這項研究的目的是使用雙能量數字乳腺攝影(DEDM)技術,改善微鈣化偵測性。用幾塊均勻和乳房相等的塑膠,由三種不同組織密度來模擬不同乳房厚度從3-7cm。用額外的一塊板子,有五種不同大小的碳酸鈣粒集群來模擬微鈣化,直徑從0.16-0.19mm。在FROC和曲線下面的面積(AZ)評估用DEDM和SEDM在乳房攝影偵測微鈣化不同。研究結果顯示用DEDM方式可以成功的觀察到微鈣化,如果乳房厚度是小於5cm,微鈣化小於0.2mm。用DEDM平均每張片子的假陽性平均數為0.0198(A_z=0.956±0.027),使用SEDM平均每張片子的假陽性平均數為0.292(A_z=0.681±0.235)。有效地使用DEDM比以往SEDM可以更準確有效的對於早期乳腺癌的微鈣化診斷。 |
英文摘要 | As microcalcifications are one of the earliest indicators of breast cancer, their detection at an early stage plays a decisive role in reducing breast cancer mortality. The purpose of this study is to improve microcalcification detectability using a dual-energy digital mammographic (DEDM) technique. Slabs of uniform breast-equivalent plastic with three different tissue densities were used to mimic various breast thicknesses from 3 to 7 cm. An additional plate with five different sizes of pre-sifted CaCO_3 grain clusters was used to simulate microcalcifications with diameters from 0.16 to 0.39 mm. Free-response receiver operating characteristics (FROC) and area under curve (A_z) value were employed to evaluate detecting sensitivity of microcalcifications using the DEDM compared to conventional single-energy digital mammography (SEDM). Using the DEDM technique, microcalcifications were successfully imaged using a breast thickness less than 5 cm when microcalcifications were smaller than 0.2mm. The average number of false-positive per image (at a 90% true-positive fraction) was 0.0198 (A_z=0.956±0.027) using DEDM compared to 0.292 (A_z=0.681±0.235) using SEDM. Microcalcifications could be more accurately and efficiently detected using the DEDM compared to the conventional SEDM, bringing reliable and promising applications on early computer aided diagnosis of breast cancer. |