查詢結果分析
相關文獻
- 乳房惡性腫瘤與良性病灶在超音速剪力波彈力量化圖上的比較
- Color Doppler Ultrasound Velocimetry of Internal Carotid Arteries in Normal Pregnancies
- High-Resolution and Color Doppler Ultrasonographic Features of Peripheral Neurogenic Tumor
- Sonographic and Color Doppler Sonographic Diagnosis of Acute Osteomyelitis: Report of One Case
- Color Duplex Sonography in the Evaluation of Varicoceles
- Color Doppler Ultrasound Evaluation of Radial Artery Occlusion in Transradial Catheterization
- Color Doppler Imaging Analysis of Ocular Vessel Flow Velocity in Glaucomatous and Normal Subjects
- Transvaginal Color Flow Doppler Ultrasonography for Detecting Acquired Arteriovenous Malformation of the Uterus
- Color Doppler Ultrasound of Spiral Arteries in Normal Second-Trimester Pregnancies
- The Effect of Meal Intake on Hepatic Feeding Vessels-Color Doppler Ultrasonographic Assessment in Normal Chinese Adults
頁籤選單縮合
| 題 名 | 乳房惡性腫瘤與良性病灶在超音速剪力波彈力量化圖上的比較=Quantitative Supersonic Shear Imaging Elastography on Benign and Malignant Breast Lesion |
|---|---|
| 作 者 | 李靜姍; 湯順昌; 劉春蘭; 江惠如; 賴亦貞; 周宜宏; 張政彥; | 書刊名 | 中華放射線技術學雜誌 |
| 卷 期 | 38:1 2014.03[民103.03] |
| 頁 次 | 頁22-28 |
| 分類號 | 416.226 |
| 關鍵詞 | 超音速剪力波彈力圖; 灰階超音波; 彩色杜卜勒超音波; 乳房影像紀錄與超音波診斷系統; Supersonic shear imaging; Gray-scale ultrasound; Color Doppler ultrasound; BI-RADS US; Breast imaging-recording and diagnostic system ultrasound; |
| 語 文 | 中文(Chinese) |
| 中文摘要 | 利用超音速剪力波彈力圖(supersonic shear imaging;SSI)獲得良性病灶與惡性腫瘤之間的彈性數值差異,並分別將其內外周圍的彈性量化數值做比較,進一步與病理切片做相關性分析。觀察BI-RADS US(The Breast Imaging Recording and Diagnostic System Ultrasound)在傳統超音波與SSI影像數值上的分類變化。本研究共收錄了12位婦女,利用Aixplorer ultrasound system(Supersonic Imagine,Aix en provence,France)機器來做SSI數值檢測,並在病灶影像最大切面內外各選取2個以上感興趣區(regions of interest;ROI)做測量。良性病灶SSI最大彈性數值與惡性腫瘤SSI最大彈性數值(38.03±19.50;137.24±75.82 p=0.004)達統計上差異。BI-RADS US分級上變化有8位。由本研究得知SSI可以提供有效的組織彈性量化值,此技術可以配合灰階與彩色杜卜勒超音波來增加乳房腫瘤診斷率並降低對良性病灶做切片檢查。 |
| 英文摘要 | The aims of this study were to compare the elasticity between benign and malignant breast lesions and to correlate the elasticity values of breast masses with histopathologic findings. We analyzed the elasticity of the tissue surrounding the mass and inside of a malignant lesion. The BI-RADS US (Breast Imaging-Recording and Diagnostic System Ultrasound) category based on conventional gray-scale ultrasound and information obtained from supersonic shear imaging (SSI) were document. The ultrasonic investigation was performed in 12 patients using the Aixplorer Ultrasound System(Supersonic Imagine, Aix en provence, France)to obtain the elasticity value with a property selected ROI. The maximum elasticity between benign and malignant lesions had significant difference (38.03±19.50 kPa vs 137.24±75.82 kPa, p=0.004). There are 8 subjects showed change in BI-RADS US category. We concluded that SSI can provide the quantitative elasticity of breast masses and can improve the diagnostic accuracy with reduce biopsy in benign lesion. |
本系統中英文摘要資訊取自各篇刊載內容。