查詢結果分析
相關文獻
- Assessment of Radiation Dose and Image Quality in Coronary Computed Tomography Angiography Using Adaptive Statistical Iterative Reconstruction and a Body Mass Index-adapted Protocol
- Detection of Coronary Artery Calcification by Ultrafast Computed Tomography in Taiwanese
- 以電子束電腦斷層評估冠狀動脈鈣化指數及診斷冠狀動脈疾病
- Diagnostic Accuracy and Safety of Dipyridamole Thallium-201 Single Photon Emission Computed Tomography in Coronary Artery Disease
- Reverse Redistribution During Dipyridamole Thallium-201 Myocardial Single Photon Emission Computed Tomography in Coronary Artery Disease
- 冠狀動脈疾病引起失能和猝死的危險
- Clinical Correlation among Thallium-201 Myocardial Perfusion SPECT, Dual-source CT, and Coronary Angiography: A Case Report
- 64-多切面電腦斷層冠狀動脈管徑狹窄與核醫心肌灌注掃描缺血程度相關性評估
- 利用量化的方法於冠狀動脈電腦斷層攝影對血管阻塞之評估
- 無靜脈注射對比劑於低劑量電腦斷層掃描急性闌尾炎之診斷價值
頁籤選單縮合
題 名 | Assessment of Radiation Dose and Image Quality in Coronary Computed Tomography Angiography Using Adaptive Statistical Iterative Reconstruction and a Body Mass Index-adapted Protocol=冠狀動脈電腦斷層掃描中輻射劑量與影像品質研究--運用適應性統計疊代重建技術與隨身體質量指數調整的掃描條件 |
---|---|
作 者 | 謝豐吉; 林昭男; 蔡宗佳; 周崇國; 許立生; 魏妙俶; | 書刊名 | Journal of Radiological Science |
卷 期 | 36:2 2011.06[民100.06] |
頁 次 | 頁79-84 |
分類號 | 416.14 |
關鍵詞 | 冠狀動脈; 電腦斷層; 身體質量指數; |
語 文 | 英文(English) |
英文摘要 | Adaptive statistical iterative reconstruction (ASIR) is a new method for reduction of the radiation dose in CT scans. We aimed to evaluate the radiation dose and image quality after employing ASIR and a body mass indexadapted protocol in coronary CT angiography. We evaluated 66 patients who underwent coronary CTA using 50% ASIR. The tube voltage (100~120 kVp), current (300~550 mA) and filter (Bowtie small and large) were chosen according to body mass index (BMI). Patients with a sinus rhythm and a heart beat ≤ 65 beats/min underwent a prospective gating (PG) scan, and the others underwent a retrospective gating (RG) scan. The image noise, signal-to-noise ratio (SNR) and effective dose were measured and calculated. The objective image quality was evaluated according to the image noise and SNR, and the subjective image quality was assessed on a 5-point scale for the coronary segments. The mean effective dose in the PG group was 1.8 ± 0.7 mSv (range: 0.3–3.2 mSv), while that in the RG group was 8.6 ± 2.4 mSv (range: 3.8–14.3 mSv). The effective dose was correlated with BMI (r = 0.52, p < 0.001). There was neither a significant correlation between BMI and image noise (r = -0.12, p = 0.362) nor between BMI and SNR (r = -0.15, p = 0.226). Of 864 segments, 851 (98.5%) were of a diagnostic image quality (score 1–3). The mean score of the subjective image quality according to the 5-point scale was 1.6 ± 0.4. The subjective image quality was not correlated with BMI (r = 0.019, p = 0.881). By using ASIR and BMI-based scanning parameters, the radiation dose was effectively lowered in comparison with previous studies of coronary CTA. The image noise and study interpretability were also preserved. |
本系統中英文摘要資訊取自各篇刊載內容。