題 名 | Iatrogenic and Fatal Arterial Air Embolism during the CT Scan |
---|---|
作 者 | Yang, Ming-shiang; Yang, Tzu-hsien; Ou, Chang-hsien; Chan, Si-wa; Chen, Tai-i; Tu, Chung-wei; Tung, Yung-wei; | 書刊名 | Journal of the Chinese Medical Association |
卷 期 | 74:4 2011.04[民100.04] |
頁 次 | 頁188-191 |
分類號 | 415.384 |
關鍵詞 | Air embolism; Iatrogenic error; Pneumocranium; |
語 文 | 英文(English) |
英文摘要 | Systemic and fatal arterial air embolism during the computed tomography (CT) scan is rarely reported in English-based literature. Iatrogenic air embolism happening during the CT scan is often related to the injector, usually venous air embolism and asymptomatic. We report one fatal and extensive systemic arterial air embolism because of one error that happened during a brain CT scan. The mechanism is different from the reported cases in the literature. The possible mechanism and pathogenesis are well discussed to alert clinicians and prevent the recurrence of such complication. |