題 名 | Application of Co-sputtered Cu-Ni Micro Metallic Strain Gage for Structure Response Monitoring |
---|---|
作 者 | Jenq, Syh-tsang; Wang, Yi-sih; Ting, Jyh-ming; Lo, Hon Seng; Young, Hong-tsu; Chuang, Li-chang; Lin, Hon-bin; | 書刊名 | Journal of Aeronautics, Astronautics and Aviation. Series A |
卷 期 | 41:2 2009.06[民98.06] |
頁 次 | 頁103-110 |
分類號 | 448.5 |
關鍵詞 | Metallic micro sensors; Micro strain gage; Piezo-resistive material; MEMS; |
語 文 | 英文(English) |
英文摘要 | This work is concerned with the development of micro strain gages made of nickle and copper alloy for mechanical static and dynamic response measurement. The magnetron sputtering technique is adopted to deposit the metallic Cu-Ni alloy film to the surface of silicon wafer and flexible polyimide substrate. Similar fabrication process has also been applied to co-sputter the micro Cu-Ni alloy strain gages on the surface of silicon wafer. It is reported that the deposition of the metallic alloy sensors on silicon wafer coated with an insulation layer can be used as a strain sensor and the X-ray diffraction examination reports that FCC microstructure is obtained and reasonably good electric resistivity is found. The line width of the current micro metallic strain gage is designed to be 30μm and the width and length of the micro strain gage is set to be 390μm and 750μm. The current microfabricated Cu-Ni strain gage is reported to be in the range of 320-350 Ω. It was reported that the current sputtered micro Cu-Ni strain gage can closely measure the structural bending strain. In addition, the impact strain measurement has also been conducted and the present developed micro strain sensor seems able to detect the dynamic mechanical response also. |
本系統中英文摘要資訊取自各篇刊載內容。