查詢結果分析
相關文獻
- Noise Distribution in Closed and Open Spaces in the Neonatal Intensive Care Unit
- Noise Distribution of an Incubator with Nebulizer at a Neonatal Intensive Care Unit in Southern Taiwan
- Noise and Related Events in a Neonatal Intensive Care Unit
- Noise Surveys in a Neonatal Intensive Care Unit
- 降低新生兒加護病房噪音分貝率
- 娛樂性活動與聽力喪失
- Restoration of Old Urban Environments--Creating a New Landscape for the Streets and Open Spaces in the Historic Quarters of Singapore
- 新生兒加護病房的院內感染
- 高速鐵路噪音防護對策--針對臺南科學園區之研究分析
- 營建工程噪音污染預防與環境管理系統
頁籤選單縮合
題 名 | Noise Distribution in Closed and Open Spaces in the Neonatal Intensive Care Unit=新生兒加護病房內密閉及開放空間的噪音分佈 |
---|---|
作 者 | 劉映君; 陳昭惠; 王德明; 遲景上; | 書刊名 | Clinical Neonatology |
卷 期 | 12:1 2005.06[民94.06] |
頁 次 | 頁26-29 |
分類號 | 419.38 |
關鍵詞 | 新生兒加護病房; 密閉空間; 開放空間; 噪音; Noise distribution; Neonatal intensive care unit; NICU; |
語 文 | 英文(English) |
英文摘要 | Introduction: Premature babies with immature organ systems are very fragile. Noise in a neonatal intensive care unit (NICU) has been known to cause many adverse effects such as hearing impairment, sleep disturbance, somatic effects and hindrance of emotional development. The aim of this study was to survey noise levels and time distribution of noise in two different spaces in our NICU Materials and Methods: We performed a noise distribution survey in our NICU at the Veterans General Hospital Taichung using two electronic sound-level meters (RION NL 21, Japan) with a central site measurement. There were two rectangular adjacent spaces (6×5 meters each) with six beds in each space. One space (room A) was a closed space with a controllable door and the other space (room B) was next to an open area without a wall between it and the nurse station. All measurements were made using the A filter and slow response time (1-second averaging) and expressed in decibels (dBA). The sound levels were presented as hourly L(subscript eq), L(subscript max) and L10. Data were analyzed using SPSS 10.0 software for Windows. Results: The hourly L(subscript eq( was 54.59 dBA in room A and 52.29 dBA in room B. The difference in the hourly L(subscript eq) was 2.3 dBA (p<0.05). The hourly L(subscript max) was 73.54 dBA in room A and 71.56 dBA in room B. The difference in the hourly L(subscript max was 1.98 dBA (p<0.05). The hourly L10 was 56.67 dBA in room A and 54.81 dBA in room B. The difference in the hourly L10 was 1.86 dBA (p<0.05). In our study, hourly L(subscript eq), L(subscript max) and L10 all exceeded the recommended levels. Conclusion: The closed space (room A) had higher noise levels than the open space (room B). The controllable doors cement walls, glass windows and incubators inside a closed space might contribute to this higher noise level. Continuous sound level monitoring of the intensive care unit is important to provide a safe environment for premature infants. |
本系統中英文摘要資訊取自各篇刊載內容。