查詢結果分析
來源資料
相關文獻
- 非最大跑步運動攝氧量與心跳率推算臨界速度之效度研究
- 百分比攝氧量與心跳率推算臨界速度之比較研究
- Isokinetic Strength and Electromyographic Analysis of Knee Muscles in Parkinsonian Patients and Normal Subjects
- 運動生物力學實務: 腓腸肌群收縮活動電位肌電圖分析
- 不同自覺能力對12分鐘跑走運動表現的影響
- 青少年游泳選手臨界速度數學推算模式之比較研究
- 長距離跑步選手的臨界速度研究
- 實驗室與田徑場跑步速度耐力模式測驗結果的比較
- An EMG-Driven Model for the Prediction of Dynamic Muscle Forces during Knee Isokinetic Exercises
- Electromyographic Comparisons between Open and Closed Kinetic Chain Knee Exercises
頁籤選單縮合
題 名 | 非最大跑步運動攝氧量與心跳率推算臨界速度之效度研究=Validation of Critical Velocity Derived from Submaximal Oxygen Intake and Heart Rate during Treadmill Running |
---|---|
作 者 | 吳忠芳; 林正常; | 書刊名 | 運動生理暨體能學報 |
卷 期 | 1 2004.09[民93.09] |
頁 次 | 頁54-65 |
分類號 | 528.9012 |
關鍵詞 | 非最大運動攝氧量; 非最大運動心跳率; 臨界速度; 攝氧量; 肌電圖; Critical velocity; Submaximal exercise time; Electromyography; |
語 文 | 中文(Chinese) |
中文摘要 | 本研究目的在探討以非大最大運動攝氧量與心跳率所推算的臨界速度(critical velocity, CV)與傳統運動至衰竭所推算之CV是否有差異存在;並以此強度持續運動30分鐘,進行氧攝氧量、心跳率與積分肌電圖等人體生理反應的變化情形分析,以便確認非最大運動攝氧量及心跳率推算CV方法之有效性。本研究以20名經常參與運動男性大學生(20.45±0.83歲、177.30±6.21公分、71.62±6.45公斤)為受試對象,受試者除了先接受一次最大攝氧量及最大心跳率測驗以外,所有受試者皆需接受四個不同強度跑步的CV測量。進行CV測量時,同時蒐集受試者之攝氧量與心跳率,以利從各強度跑步至90%、80%、和70%目標攝氧量與心跳率之時間推算非最大象動攝氧量與心跳率CV。結果發現以傳統最大努力跑步至衰竭時間所推算的CV(3.54±0.318m/s)與CV□、CV□與CV□(3.64±0.387、3.56±0.410和3.60±0.354m/s)無顯著差異時。同時,本研究以實用性較高及估計標準差最低之CV□持續30分鐘運動時,心跳率會隨著運動時間的增加而上升,RMS下降、攝氧量與MPF則無顯著變化,顯示以此強度運動30分鐘,並無疲勞現象發生。 |
英文摘要 | The purposes of this study were (1) to examine the difference between critical velocity (CV) derived from submaximal exercise time and maximal exercise time, and (2) to examine the validity of CV derived from submaximal exercise time. Subjects were 20 college students (20.45±0.83yrs, 1773.0±6.21cm, 71.62±6.45kg). Participants performed five exhaustive treadmill tests and a 30-min continuous treadmill tests at CV. The purpose of the first test session was to determine VO□ HRmax and ventilatory threshold. At the next four sessions, each subject performed four exhaustive constant velocity test (3.5m/sec~6,/sec). During each test, expired gases and HR were analyzed. CV was derived from submaximal exercise VO□ and HR at each velocity. Secondly, participants performed a 30-min continuous treadmill tests at their CV. During the test, the VO□ Hr and electromyography (RMS & MPF) responses from treadmill were examined, and the validity of CV derived from submaximal exercise time were determined. The results were: (1) CV derived from submaximal exercise time (CV), 3.64±0.387; CV□, 3.56±0.410; CV□, 3.60±0.354m/s and maximal exercise time was (3.54±0.318m/s) not significantly different. (2) When running a 30-min continuous treadmill tests at their CV, HR increased with time, but RMS, MPF and VO□ remain unchanged) |
本系統中英文摘要資訊取自各篇刊載內容。