查詢結果分析
來源資料
相關文獻
- Peritoneal Scintigraphy for the Assessment of Dialysate Leakage in Patients on Continuous Ambulatory Peritoneal Dialysis
- Diagnosis of Peritoneopleural Communication with [fee6]Tc-MAA Scintigraphy in a Patient with Continuous Ambulatory Peritoneal Dialysis: A Case Report and Literature Review
- 連續可活動性腹膜透析自我效力量表之建立與測試
- Peritonitis in Patients on Continuous Ambulatory Peritoneal Dialysis
- 紅斑性狼瘡併尿毒症的連續可活動性腹膜透析患者發生腸病變併營養不良症候群
- 一位罹患末期腎病接受連續可活動性腹膜透析患者之護理經驗
- Unusual Bilateral Peritoneopleural Communication Associated with Cirrhotic Ascites:Detected by TC-99M Sulphur Colloid Peritoneoscintigraphy
- Peritoneal Scintigraphy for Diagnosing Periumbilical Leakage in a Patient on Continuous Ambulatory Peritoneal Dialysis
- Incidence of Exit-Site Infection with Various Exchange Systems in Continuous Ambulatory Peritoneal Dialysis
- Clinical and Radiological Manifestations of Pulmonary Sequestration
頁籤選單縮合
題 名 | Peritoneal Scintigraphy for the Assessment of Dialysate Leakage in Patients on Continuous Ambulatory Peritoneal Dialysis=腹膜閃爍攝影於連續可活動性腹膜透析患者的透析液滲漏之診斷價值 |
---|---|
作 者 | 吳佩珊; 李碧芳; 邱南津; 姚維仁; 黃建鐘; 王明誠; | 書刊名 | 核子醫學雜誌 |
卷 期 | 14:1 2001.03[民90.03] |
頁 次 | 頁11-18 |
分類號 | 415.816 |
關鍵詞 | 連續可活動性腹膜透析; 腹膜閃爍攝影; 鎝-99m-MAA; 透析液滲漏; 水胸; Continuous ambulatory peritoneal dialysis; Peritoneal scintigraphy; [fee6]Tc-MAA; Hydrothorax; Peritoneal leakage; |
語 文 | 英文(English) |
中文摘要 | 背景:連續可活動性腹膜透析是未期腎病常用的治療方其併發症包括透析液滲漏,如水胸、腹部和外陰部水腫,本篇報告闡述腹膜閃爍攝影於透析液滲漏的診斷價斷。 方法:從1991年6月到1999年10月,10個接受連續可活動性腹膜透析而懷疑透析液滲漏的患者接受閃爍攝影檢查。腹膜閃爍攝影的步驟是經由腹膜透析管(Tenckhoff catheter)灌入含有111 MBq(3mCi)鎝-99m-MAA的透析液到腹膜腔內,以加馬攝影機收集動態影像及六小時以內的靜態影像。 結果:在這10位患者的閃爍攝影檢查中,腹膜閃爍攝影偵測到5個腹胸膜交通、3個肚臍周圍滲漏、1個滲漏到右側陰囊、1個病人滲漏到右側大陰唇。一位肚臍周圍滲漏患者經治療後,追蹤腹膜閃爍攝影顯示仍扲續有滲漏現象。另一位大陰唇滲漏偌右側大陰唇。一位肚臍周圍滲漏患者經治療後,追蹤腹膜閃爍攝影顯示仍扲續有滲漏現象。另一位大陰唇滲漏忠者,第二次檢查顯示有複部缺損滲漏,第三次追蹤影像則恢復正常。 結論:我們的結果顯示腹膜閃爍攝影對於使用連續可活動性腹膜透析而導致透析液滲漏的病人來說,是一種高敏感度、沒有侵襲性、相當方便、並且具有診斷價值的檢查方法。 |
英文摘要 | Background: Continuous ambulaory peritoneal dialysis (CAPD) has several advantages. However, some complications including dialysate leakage may occur. In this study, we investigated the value of peritoneal scintigraphy in evaluating dialysate leakage in patients undergoing CAPD. Methods: Ten patients underwent CAPD between June 1991 and October 1999 and suspected to have dialysate leakage were included in this study. Peritoneal scintigraphy was performed after administration of 111 MBq (3mCi) of 99m Tc-MAA in dialysis solution into the perioneal avity via the Tenckhoff catheter. Initial dynamic imaging and subsequent images over a 6-h period were obtained. Results: Dialysate leakage was demonstrated by peritoneal scintigraphy in all 10 patients, including 5 peritoneopleural communication, 3 periumbilical leakage (two espisodes in patient 6), 1 leakage into the right hemiscrotum, and 1 (patient 9) leakage into the right labia major at he first time and leakage via abdominal wall defect at the second time. a follow-up scan of patient 9 had negative result. Conclusion: Peritoneal scintigraphy is a highly sensitive, non-invasive, and convenient procedure with diagnostic value in evaluating dialysate leakage encountered in patients on CAPD. |
本系統中英文摘要資訊取自各篇刊載內容。