查詢結果分析
來源資料
相關文獻
- 裝置脊椎內固定器患者之軀幹功能
- 臺灣成人軀幹肌力之評估
- A Lumbar Motion Study of Spondylitis Patients
- Comparison of Stabilities between Obliquely and Conventionally Inserted Bagby and Kuslich Cages as Posterior Lumbar Interbody Fusion in a Cadaver Model
- 脊椎穩定運動簡介
- 芭蕾舞者的脊椎傷害
- The Effects of Low-Impact Dance on Knee Torque and Lower Extremity Mobility in Middle-Aged and Older Women
- Postoperative Spinal Deep Wound Infection: A Six-year Review of 3230 Selective Procedures
- Peripheral Blood T Cell Receptor Vβ Gene Expressions in Patients with Ankylosing Spondylitis and their First-Degreee Relatives
- 僵直性脊椎炎病人身體心像之相關因素
頁籤選單縮合
題 名 | 裝置脊椎內固定器患者之軀幹功能=Functional Evaluation of Patients with Spinal Instrument |
---|---|
作 者 | 詹美華; 鄭誠功; 曾永輝; 陳昭瑩; 簡盟月; 陳博光; | 書刊名 | 中華民國物理治療學會雜誌 |
卷 期 | 23:1 1998.01[民87.01] |
頁 次 | 頁1-11 |
分類號 | 416.61 |
關鍵詞 | 脊椎; 脊椎內固定器; 力矩; 活動度; Spine; Spinal instrumentation; Peak torque; Mobility; |
語 文 | 中文(Chinese) |
中文摘要 | 很多下背痛患者接受手術治療時脊椎常常會裝置內固定器。這類患者手術後的脊 椎功能到目前為止一直不見相關報告。本研究之目的即利用客觀的評估方法評估這類患者手 術後脊椎的活動度、活動速度及背肌與腹肌之肌力;另以問卷方式得知患者對手術後脊椎功 能的滿意度。 本研究是追蹤 52 位台大醫院骨部資深醫師之患者、 以腰椎活動測試儀( lumbar motion monitor )測驗腰椎三度空間的活動度及活動速度。 以 Cbex 6000 ( TEF )等速肌力測試儀( isokinetic dynamometer )測驗脊椎之背肌與腹肌在 0 ° / 秒,30 ° / 秒,60 ° / 秒,90 ° / 秒,120 ° / 秒等 5 種角速度下之力矩。 另以 86 位年 齡、身高、體重相仿的健康無背痛受試者為對照組,結果發現:活動度及活動速度以矢狀面 ( sagittal plane )喪失最多,尤其是速度方面,多數患者僅為健康者的 30-40%。 年齡 大於 50 歲以上的女性患者,其脊椎在各方面的功能表現都較差,包括背肌、腹肌之快、慢 速力矩、活動角度及活動角速度。本研究之結果讓大家了解:脊椎裝置內固定器之患者,手 術後活動度及肌力之訓練確實有加強之必要。 |
英文摘要 | After failure of conservative treatment, many lower back pain patients under went surgical procedures with spinal instrumentation. In the literature, there were few reports concerning the spinal function such as range of motion, angular velocity and trunk strength in this type of patient population. Fifty-two patients with spinal instrumentation were selected. Their spinal range of motion and angular velocity were assessed with lumbar motion monitor, and their peak torque of trunk flexor and extensor at various speed were evaluated with Cybex 6000 TEF isokinetic dynamometer. Eighty-six age matched healthy subjects withoyt back pain served as a control group. This study showed the following results: 1.All patients showed a decrease in their spinal range of motion, angular velocity and peak torque of trunk flexor and extensor at various speeds. 2.the greatest reduction in lumbar function, both range of motion and peak torque, were found on the sagittal planve and at 120 ° /sec of the isokinetic testing speed. 3.Among all patients, females older than 50 years of age showed greatest lose in spinal function, an indication that the functional capacities in these patients were affected by both gender and age. |
本系統中英文摘要資訊取自各篇刊載內容。