查詢結果分析
來源資料
相關文獻
- Rapid Recovery of Spontaneous Baroreflex after Sevoflurane Anesthesia in Ambulatory Surgery
- Aggregative Behavior of the Swordtip Squid (Loligo Edulis) Under Fishing Lights in the Coastal Waters of Northern Taiwan
- 衛生掩埋場滲出水量條件性異質變異時序模式
- 序列分析在諮商歷程研究的應用--以兩組諮商個案為例
- 分子流行病學:核酸複製及基因序列分析之應用
- 序列分析在諮商歷程研究的應用
- 時序與灰色時流量預測模式效能比較
- 降雨量及地下水位之趨勢與變動分析
- 由苦瓜硬化病果上所分離之矮南瓜嵌紋病毒鞘蛋白基因之分析
- 核四廠址之濱鹽寮灣仔稚魚群集的消長探討
頁籤選單縮合
題名 | Rapid Recovery of Spontaneous Baroreflex after Sevoflurane Anesthesia in Ambulatory Surgery=使用麻醉氣體Sevoflurane對門診手術病人自主神經恢復的影響 |
---|---|
作者 | 黃謙琳; 黃慧薰; 趙安怡; 王永彬; 蔡勝國; Huang, Chien-lin; Huang, Hui-hsun; Chao, Anne; Wang, Yong-ping; Tsai, Shen-kou; |
期刊 | 麻醉學雜誌 |
出版日期 | 20010300 |
卷期 | 39:1 2001.03[民90.03] |
頁次 | 頁23-26 |
分類號 | 416.5 |
語文 | eng |
關鍵詞 | 血壓監測器; 感壓反射; 序列分析; Blood pressure monitors; Baroreflex; Spontaneous sequence analysis; Sevoflurane; |
中文摘要 | 背景:Sevoflurane具備作用快,甦醒快,代謝快且不影響心血管及呼吸系統等待性。本實驗目的在評估sevoflurane用於門診手術麻醉後自主感壓反射恢複的情形。方法:記錄10位麻醉體位評議爲壹級且接受常規門診婦科子宮內膜刮除術的病人之動脈壓訊號和心跳R-R interval,利用序列分析(sequence analysis)計算自主感壓反射敏感度(spontaneous baroreflex sensitivity, SBR),比較術前、術中、術後5分鍾及術後10分鍾所得到之SBR值之差異。結果:術中(12.2±2.1 ms/mmHg)及術後5分鈡(15.8±1.8 ms/mmHg)和術前(28.6±4.9ms/mmHg)有明顯差異。術後10分鍾(28.8±5.7 ms/mmHg)和術前則無明顯差異。結論:使用麻醉氣體sevoflurane對門診手術病人之自主神經系統的影響,於關麻藥後10分鍾內即恢複術前清醒時之感壓反射強度。 |
英文摘要 | Background: Although sevoflurane seems to have fulfilled the criteria of ideal anesthetic agent for ambulatory surgery, its effects on intraoperative alteration and postoperative recovery of arterial b aroreflex have not been well documented. This study assessed the time required for patients anesthetized with sevoflurane to regain their baseline baroreflex after ambulatory surge ties. Methods: Ten ASA class I female patients scheduled for minor gynecological operation (D&C) were enrolled in this study. Spontaneous baroreflex sensitivity (SBR) calculated by sequence analysis of beat-to-beat variations in systolic arterial pressure and R-R intervals was recorded before anesthesia (Baseline), during anesthesia (Anesthesia), five mm after operation (Post-op 1) and ten min after operation (Post-op 2). Data obtained from Anesthesia, Post-op 1, and Post-op 2 was compared with the Baseline. Results: SBR value determined in Baseline group (28.6±4.9 ms/mmHg) was significantly different from Anesthesia group (12.2±2.1 ms/mniHg) and Post-op 1 group (15.8±1.8 ms/mmHg). Patients regained their conscious baseline baroreflex sensitivity within ten miii after sevoflurane was switched off. Conclusions: Sevoflurane anesthesia depresses SBR and provides a quick SBR recovery upon emergence. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。