查詢結果分析
相關文獻
- Determination of Fourteen Elements in Bone Samples Using Inductively Coupled Plasma (ICP) Analysis
- 鑽洞減壓術治術早期非創傷性股骨頭缺血性壞死
- Vascularized Iliac Bone Graft for Treating Avascular Necrosis of the Femoral Head
- Avascular Necrosis of the Femoral Head Following Intertrochanteric Fracture: A Report of Two Cases
- 可吸收性再生膜於牙科種植體之臨床應用--病例報導
- 人體骨頭「軟骨」上刀器紋痕之鑑驗
- Hip Arthroplasty for Osteonecrosis in Patients with Systemic Lupus Erythematosus
- 牽拉肘--小兒最常見的脫臼
- Evaluation Femoral Head Bone Grafts Used for Acetabuloplasty in Total Hip Replacement
- 原發性股骨頭壞死
頁籤選單縮合
題 名 | Determination of Fourteen Elements in Bone Samples Using Inductively Coupled Plasma (ICP) Analysis=以感應耦合電槳儀測定臺灣人體骨中十四種元素之濃度 |
---|---|
作 者 | 郭憲文; 郭世明; 吳錦景; 邱明珠; | 書刊名 | 中臺灣醫學科學雜誌 |
卷 期 | 6:3 2001.09[民90.09] |
頁 次 | 頁125-132 |
分類號 | 410.1644 |
關鍵詞 | 骨頭; 感應耦合電槳分析; 多種元素; Bone; Inductively couple plasma analysis; ICP; Multi-elements; |
語 文 | 英文(English) |
中文摘要 | 目的:有關人體元素濃度之相關研究較多如血液及尿液,但人體骨中元素濃度之研究則較少,且骨中元素濃度與生理作用有關。因此,本研究之目的在評估以感應耦合電槳儀 (ICP-AES) 分析國人骨中之14種元素之適當分析條件。方法:77 件骨頭樣本來自中部某醫學中心經微波消化之前處理,再以感應耦合電槳原子發射儀分析,測試三個適當儀器分析條件包括樣本吸收率,氬氣之流速及硝酸之濃度。結果:顯示元素偵測極限範圍從1 μg/L(鈷、錳及鎳) 至55 μg/L(鉛), 而樣本吸收率及氬氣最適流速分別為1.33mL/min及0.35 l/min,硝酸最適之濃度則為 1M。在人體骨中元素的量以錳 (0.7 μg/g)及鎘 (1.2 μg/g) 濃度最低,鈣 (82007.9 μg/g) 與鎂 (3005.2 μg/g) 濃度最高,不過本研究骨中所含元素濃度變異性較大,除銅原元素外,人體骨中所含元素濃度在男女性並無統計性之差異。結論:應繼續探討影響人體骨中元素濃度之相關因素,並進一步確定以感應耦合電槳儀分析骨中元素之最適條件。 |
英文摘要 | Objectives: There have been many studies of the concentrations of elements in blood and urine, but few studies have focused on the concentrations of elements in bone. The elements in bone play important roles in a variety of physiological processes. The objective of this study was to assess the optimum conditions for measuring the concentrations of 14 elements in human bone samples. Methods: Seventy-seven bone samples were collected from bone surgery patients and pretreated using a microwave digest. Inductively couple plasma-atomic emission spectroscopy (ICP-AES) analysis was used to determine the optimal conditions for three variables:sample uptake rate, flow rate of Argon gas (Ar) into the nebulizer and concentrations of nitric acid. Results: The detection limit of elements ranged from 1 μg/L (Co, Mn and Mg) to 55 μg/L (Pb). The optimal sample uptake rate and the optimal flow rate of Ar into the nebulizer were found to be 1.33 ml/min and 0.351/min, respectively. The optimum nitric acid concentration was 1M. Mn (0.7 μg/g)and Cd (1.2 μg/g)in bone samples were present in the lowest concentrations, and Ca (82007.9 μg/g) and Mg (3005.2 μ g/g) had the highest concentrations. Except for Cu, there were no significant differences in element concentrations between males and females. There was a high variation in element concentratios among the bone samples. Conclusions: Further research is needed to investigate the factors that influence the concentrations of elements in bone. The optimal conditions for bone-element analysis using ICP- AES as recommended by the authors was confirmed in this study. |
本系統中英文摘要資訊取自各篇刊載內容。