題名 | 煙囪排氣連續監測設施之設置與管理=The Installation and Management of Continuous Emission Monitoring System of Satck |
---|---|
作者姓名(中文) | 謝雲生; | 書刊名 | 技術與訓練 |
卷期 | 25:1=200 2000.02[民89.02] |
頁次 | 頁99-105 |
專輯 | 能源與環保專集 |
分類號 | 445.98 |
關鍵詞 | 煙囪排氣連續監測設施; 相對準確度測試查核; 相對準確度查核; 鋼瓶氣體查核; 現址式監測儀; Continuous emission monitoring system; CEMS; Relative accuracy test audit; RATA; Relative accuracy audit; Cylinder gas audit; In-situ type monitoring instrument; |
語文 | 中文(Chinese) |
中文摘要 | 本文探討煙囪排氣連續監測設施之法令要求,所需之軟、硬體、發包、施工、驗收等設置之注意事項,及設置後之操作、維護、管理。期對設備的選用、施工、測試、驗收與運轉管理提供有利之參考,以確保監測設施能符合法令與管理之需求。 |
英文摘要 | The purpose of present paper is in reviewing the regulations of continuous emission monitoring system (CEMS) to stack such as the software and hard- ware specifications, construction and inspection, the operation, maintenance and management after installation. Based on the above approach, the QA /QC of CEMS would meet the requirements of EPA regulations, and benefit the management of operation. |