查詢結果分析
來源資料
相關文獻
- Unexpected Left Endobronchial Intubation in a Case of Turner's Syndrome
- HELLP Syndrome with Antepartum Pulmonary Edema--A Case Report
- Ephedrine-Induced Complete Atrioventricular Block with Ventricular Asystole during Rapid Concomitant Phenytoin Infusion: A Case Report
- Epiglottic Hematoma Secondary to Endotracheal Intubation
- 臺灣地區慢性脊髓損傷病患排尿處置之調查報告
- 小兒使用TPN引起的併發症
- 淺談糖尿病及其併發症
- 難忘的病人--民俗療法之併發症
- Clinical Experience with Ventricular Endomyocardial Biopsy in Chinese Heart Transplant Patients: A Four-Year Survey of 1,208 Consecutive Procedures
- Subcutaneous Emphysema and Pneumomediastinum Associated with Labor and Delivery
頁籤選單縮合
題 名 | Unexpected Left Endobronchial Intubation in a Case of Turner's Syndrome=Turner's症候群在心包引流後發生左側支氣管內管置入之病例報告 |
---|---|
作 者 | 劉文競; 黃昌博; 鄭嘉遜; 吳世銓; 許汝寧; 譚培炯; | 書刊名 | 麻醉學雜誌 |
卷 期 | 35:4 1997.12[民86.12] |
頁 次 | 頁253-256 |
分類號 | 416.52 |
關鍵詞 | Turner's症候群; 併發症; 左側支氣管內管置入; Turner's syndrome; Complication; Left endobronchial intubation; |
語 文 | 英文(English) |
中文摘要 | 在處理Turner's症候群的病人的全身麻醉時,麻醉科醫師可能會遭遇插管困難的 現象。我們提出一個Turner's症候群的麻醉病例報告。雖然順利的使用光纖內視鏡的幫助, 經鼻孔插入氣管,但在手術進行中卻意外的滑入左側支氣管而造成右肺塌陷,所以在全身麻醉 下,即便是持續地使用聽診器監聽左肺呼吸聲,在發生呼吸道壓力上升或病人缺氣情形下,要 考慮是否氣管內管滑入左側支氣管,尤其是頸部較短的病人。 |
英文摘要 | Patients with Turner's syndrome present a multiplicity of cardiovascular and airway abnormalities. We describe a case of Turner's syndrome with pericardial effusion who experienced an inadvertent endobronchial intubation due to displacement of the endotracheal tube immediately after the pericardial drainage. A sudden increase of airway pressure and decrease of oxygen saturation in the presence of breathing sound audible via the chest piece placed on the left hemithorax first misled us to call our attention to sputum impaction. No sputum was obtainable from airway suction. Inadvertent bronchial intubation was highly suspected at the post- anesthesia room when a decrease of right side breathing sound was noted together with a progressive fall of oxygen saturation. Emergent chest x-ray confirmed the diagnosis. It was thought that the mishap took place early in the act of or following the pericardial drainage. Our case serves as evidence once again to emphasize the possibility of endobronchial intubation due to displacement of endotracheal tube during anesthesia and the importance of monitoring to guard against inadvertent bronchial intubation, particularly in patients with associated problems such as Turner's syndrome with huge pericardial effusion. |
本系統中英文摘要資訊取自各篇刊載內容。