查詢結果分析
相關文獻
- Semiquantifying Striatal Dopamine Transporter Availability with CT-based ROI in a Hybrid SPECT/CT System is a Highly Reproducible Method
- Semiquantification of Tc-99m TRODAT-1 SPECT: Comparison between DaTQUANT and MRI-Based ROI
- 傷寒論、金匱要略與溫病條辨治黃疸方劑對ANIT誘發實驗性黃疸性肝炎的比較研究
- 溫病條辨中焦濕溫疸證處方治療ANIT誘發大白鼠膽小管性肝炎的效果
- 單次劑量鎝-99m-HMPAO腦部造影於癲癇間期和癲癇後期不同的表現
- 應用類神經網路於帕金森氏症SPECT腦血流灌注影像之辨識
- SPECT/CT系統的發展與臨床應用
- Incremental Values of Tl-201 Myocardial Single Photon Emission Computed Tomography and Contrast-Enhanced Multi-Detector Computed Tomography in Patients with Myocardial Infarction
- Normal Pressure Hydrocephalus : Scintigraphic Findings on SPECT/CT Image
- Comparison of Automated 4D-MSPECT and Visual Analysis for Evaluating Myocardial Perfusion in Coronary Artery Disease
頁籤選單縮合
題 名 | Semiquantifying Striatal Dopamine Transporter Availability with CT-based ROI in a Hybrid SPECT/CT System is a Highly Reproducible Method=在SPECT/CT系統中使用電腦斷層影像圈選ROI半定量分析紋狀體多巴胺轉運體攝取是一種具有高度再現性的方法 |
---|---|
作 者 | 徐健欽; 張雁翔; 王佩文; 湯淑雯; 黃永成; 邱南津; | 書刊名 | Annals of Nuclear Medicine and Molecular Imaging |
卷 期 | 26:3 2013.09[民102.09] |
頁 次 | 頁86-90+a7 |
分類號 | 414.93 |
關鍵詞 | 多巴胺轉運體影像; 半定量分析; 單光子斷層造影; 鉻-99m TRODAT-l; Dopamine transporter imaging; Semiquantitative analysis; SPECT/CT; Tc-99m TRODAT-1; |
語 文 | 英文(English) |
中文摘要 | 背景:可靠的半定量分析方法有助於多巴胺轉運體影像的判讀,單光子斷層造影(SPECT/CT)系統可以 提供解剖學與功能性影像的準確對位。本硏究目的是藉由同一觀察者間與不同觀察者間的再現性來評 估在SPECT/CT系統中利用電腦斷層影像圏選R0I半定量分析紋狀體多巴胺轉運體攝取是否可行。 方法:共有四十三位臨床病人接受搭-99mTRODAT-腦部SPECT/CT檢查納入這項回顧性硏究。在電腦 斷層影像上手動圈選紋狀體、尾核、殼核以及枕葉皮質的R0I,然後將R0I轉移到SPECT影像上。以紋 狀體、尾核、殼核R0I的平均計數除以枕葉皮質R0I的平均計數分別計算攝取率(SUR、CUR、PUR)。 結果:使用電腦斷層影像圏選R0I方法,同一観察者間在SUR、CUR、PUR的差異平均分別爲3.04 土 2.82%、4.73 ± 4.71%、3.89 ± 3.24%,不同觀察者間在SUR、CUR、PUR的差異平均分別爲3.89 ± 3.18%、 5.48 ±4.36%、4.50 ±3.83%。Bland-Altman分析法顯示同一観察者間在SUR、CUR、PUR的誤差[一致性範 圍]分別爲0.02 [-0.09, 0.13]、0.03 [-0.15,0.21]、0.02 [-0.13,0.16],不同觀察者間在SUR、CUR、PUR的誤 差[一致性範圍]分別爲0.01 [-0.14,0.16] ' -0.03 [-0.23,0.17]、0.03 [-0.14,0.19]。 結論:在SPECT/CT系統中利用電腦斷層影像圈選R0I半定量分析紋狀體多巴胺轉運體攝取是一種具有 高度再現性的方法。 |
英文摘要 | Background:A reliable method for semiquantifying striatal dopamine transporter (DAT) availability on DAT SPECT can reinforce the visual interpretation in clinical practice. A hybrid SPECT/CT system can provide accurate registration of anatomical and functional images. The aim of this study is to evaluate the feasibility of CT-based region of interest (ROI) for semiquantifying DAT availability in a hybrid SPECT/CT system by assessing its intra- and inter-observer reproducibility. Methods:Forty-three clinical consecutive patients referred for Tc-99m TRODAT-1 brain SPECT/CT were enrolled in this retrospective study. ROIs of the caudate, putamen, and occipital cortex were manually delineated on the CT image and transferred to the SPECT image. The striatal, caudate, and putamen uptake ratios (SUR, CUR, PUR) were calculated as mean counts of striatal, caudate, and putamen ROIs divided by mean counts of occipital ROI, respectively. Results:Using CT-based ROI delineation in Tc-99m TRODAT-1 brain SPECT/CT, intra-observer variabilities of SUR, CUR, and PUR were 3.04 士 2.82%,4.73 士 4.71%, and 3.89 士 3.24%,while inter-observer variabilities were 3.89 士 3.18%,5.48 士 4.36%, and 4.50 士 3.83%,respectively. Bland-Altman analysis showed that intra-observer biases [limits of agreement] were 0.02[0.09, 0.13], 0.03[0.15, 0.21], and 0.02[0.13, 0.16]; inter-observer biases were 0.01 [0.14, 0.16],0.03[0.23,0.17], and 0.03[0.14, 0.19], respectively. Conclusion:CT-based ROI delineation for semiquantifying striatal DAT availability in a hybrid SPECT/CT system is a highly reproducible method. |
本系統中英文摘要資訊取自各篇刊載內容。