查詢結果分析
相關文獻
- Continuous Wavelet Transform Applied to the Overlapping Absorption Signals and Their Ratio Signals for the Quantitative Resolution of Mixture of Oxfendazole and Oxyclozanide in Bolus
- 多輻射源複雜脈波訊號之抵達時差定位法則研析
- 時空合域連續小波轉換應用於近海波場影像的波速與群波速度分析
- Analysis of Moiré Pattern for Micro-range Measurements based on Continuous Wavelet Transform
- 精軋機傳動元件磨耗對振動之影響
- 連續小波轉換於斜張橋之模態分析
- 複數連續小波轉換評估基樁長度之試驗研究
頁籤選單縮合
題名 | Continuous Wavelet Transform Applied to the Overlapping Absorption Signals and Their Ratio Signals for the Quantitative Resolution of Mixture of Oxfendazole and Oxyclozanide in Bolus=連續小波轉換應用於藥丸中Oxfendazole及Oxyclozanide混合物定量解析之重疊吸收訊號及比例訊號 |
---|---|
作者姓名(外文) | Dinç, Erdal; Baleanu, Dumitru; | 書刊名 | 藥物食品分析 |
卷期 | 15:2 2007.06[民96.06] |
頁次 | 頁109-117+207 |
分類號 | 418.43 |
關鍵詞 | 連續小波轉換; 零點偵測技術; 比例光譜; Oxfendazol; Oxyclozanide; Continuous wavelet transform; Zero-crossing technique; Ratio spectra treatment; |
語文 | 英文(English) |
中文摘要 | 連續小波轉換(CWT)應用於藥丸中oxfendazole(OXF)及 oxyclozanide(OXY)混合物定量解析之重疊吸收訊號及比例訊號,而不需使用任何化學前處理。針對訊號處理,墨西哥帽函數(MEXH)及 Morlet(MORL)連續小波轉換在小波族群裡是合適的。首先,MEXH-CWT配合零點偵測技術直接應用於OXF及OXY藥物,在波長 255-365nm區間(OXY為328.7nm,OXF為309.3 nm),藉由測量MEXH-CWT振幅得到此兩項藥物之校正圖。接著,利用MORL-CWT分別找出OXY及OXF比例光譜之顯著波峰解析度。CWT振幅最大及最小值、波峰對波峰,以及零點偵測技術均使用於校正圖。藉由分析合成混合物及運用標準品添加技術,進行CWT-零點偵測及比例光譜-CWT技術確效,結果發現有良好的準確性、精確性及再現性。 |
英文摘要 | Continuous wavelet transform (CWT) was applied to the overlapping absorption signals and their ratio signals for the quantitative resolution of mixture of oxfendazole (OXF) and oxyclozanide (OXY) in bolus without using any pre-chemical treatment. Mexican hat function (MEXH) and Morlet (MORL) continuous wavelet transforms (MEXH-CWT and MORL-CWT) for signal treatments were found to be suitable among the wavelet families. In the first step MEXH-CWT together with zero crossing technique is directly applied to the overlapping absorption spectra of OXF and OXY drugs and their calibration graphs were obtained by measuring the MEXH-CWT amplitudes at 328.7 nm for OXY and at 309.3 nm for OXF in the wavelet domain of 255-365 nm. In the second step MORL-CWT is used for finding the significant peak resolution of the ratio spectra of OXY and OXF respectively. The maxima and minima of CWT amplitudes and peak-to-peak and zero-crossing techniques were used for the calibration graphs. The method performances of CWT-zero crossing and ratio spectra-CWT techniques were validated by analyzing the synthetic mixtures and by applying the standard addition technique, and successfully accuracy, precision and reproducibility results were reported. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。