查詢結果分析
相關文獻
- Improvement of Accidental Coincidence Estimation for Scanditronix PC2048/4096 PET Scanners
- Generalized Gray Codes with Applications
- Distributed Broadcasting Algorithms in Rotator Graphs
- Fractal Image Coding Using Projection-Based Classification and Variable Shape Matching
- 以類神經網絡模式分析颱風降雨與半分布並聯式水庫概念模式模擬颱洪歷線之串聯應用
- 線性軸幅路網接駁系統最適整合區位、路線與排班模式之研究
- 都市計畫草圖替選方案分析模式之實例研究
- MUSCL Type Algorithm for Acoustic Wave Equations in Heterogeneous Media
- 運用類神經網路於股價指數之套利--以日經225指數為例
- Genetic Algorithm Approach for Designing Fir Hilbert Transformers and Differentiators
頁籤選單縮合
題 名 | Improvement of Accidental Coincidence Estimation for Scanditronix PC2048/4096 PET Scanners=Scanditronix正子斷層掃描儀意外偶合估計方式的改進 |
---|---|
作 者 | 陳祺賢; 余金龍; 吳良治; 劉仁賢; | 書刊名 | Journal of Medical and Biological Engineering |
卷 期 | 24:3 2004.09[民93.09] |
頁 次 | 頁121-123 |
分類號 | 414.93 |
關鍵詞 | 正子放射斷層造影術; 閃爍計數; 演算法; Positron emission tomography; Scintillation counting; Algorithms; |
語 文 | 英文(English) |
中文摘要 | 正子放射斷層造影(positron emission tomography, PET)時隨機產生之意外偶合(accidental coincidence),或稱隨機事件(randoms),是降低造影精確度的原因之一。然而,與一般人所以為的情況相反的是,儘管已使用PET廠商所提供的軟/硬體作意外偶合校正,意外偶合仍可能對PET的定量造成顯著影響。本文研究Scanditronix正子斷層掃描儀原廠所提供意外偶合校正方式並提出簡單的修正,藉此求得更佳的結果。方法:以圓柱形做為假體,以兩種不同起始放射強度,但固定的短時間間隔連續收集多筆資料,每次共收集12小時。選擇不同時間區段內不同加總取像時間之所有資料相加的總和,可得八種不同長/短掃描時間及高/低事件計數之資料。藉此我們可以比較原廠方法所估測的隨機事件數與改良後所估測的隨機事件數。結果:當取像時間遠大於放射核種之半衰期時,原廠估測之隨機事件數遠不如修正後所估測之隨機事件數正確。結論:本文中對原廠提供方法所做的簡單修正,可明顯改善對意外偶合的估測。 |
英文摘要 | Accidental coincidence (randoms) is one of the factors that degrade the accuracy of positron emission tomography (PET). In contrast to widely-held beliefs, we have previously shown that randoms can significantly affect quantitative PET even after current hardware/software randoms correction is applied. In order to have better estimation of randoms for our Scanditronix scanner, we investigated the limitation of the vendor-provided randoms estimation and proposed a simple modification. Methods: Multiple short-frame data of a homogeneous circular cylinder were collected over 12 hours. Summed data were generated by summing up selected frames. Randoms of the summed data estimated by the vendor-provided method and our modified method were compared. Results: The vendor-provided randoms estimation did not work as well as the modified method when frame duration is much larger than the half-life of the radioactive agent used. Conclusion: Our minimal modification of the vendor-provided method significantly improves randoms estimation. |
本系統中英文摘要資訊取自各篇刊載內容。