題 名 | 大白鼠血漿中褪黑激素之高效液相層析分析=Determination of Melatonin in Rat Plasma by High Performance Liquid Chromatography with Electrochemical Detection |
---|---|
作 者 | 周淑姿; 彭彩鳳; | 書刊名 | 藥物食品分析 |
卷 期 | 5:2 1997.06[民86.06] |
頁 次 | 頁131-137 |
分類號 | 415.121 |
關鍵詞 | 褪黑激素; 高效液相層析; 電化學偵測; 清除率; Melatonin; High performance liquid chromatography; HPLC; Electrochemical detection; ECD; Clearance; |
語 文 | 中文(Chinese) |
中文摘要 | 本研究利用高效能液相層析儀配合電化學偵測器以定量分析大白鼠血漿中褪黑激 素之濃度, 結果顯示:此分析方法具有良好之線性關係 (R^ 2=1), 偵測極限為 1.3ng/ml ;且利用乙氰直接將血漿樣品液去蛋白並同時萃取褪黑激素,以簡化縮短前處理之步驟,其 添加於血漿樣品液之回收率為 92 ~ 99%;同日內之穩定性試驗其偏差係數為 1.5 ~ 2.2%, 異日間之偏差係數為 3.5 ~ 5.0%, 顯示此分析方法具有簡單、快速、高準確性且再現性好 之優點。利用此分析方法以探討 Sprague Dawley 品系大白鼠血漿中褪黑激素之清除率,經 由動物體股靜脈給予褪黑激素 (0.67 mg/Kg),結果顯示褪黑激素在注射 0.5 ~ 1.0 小時後於血液中濃度達到最高峰,於 0.5、1.0、1.5、2.0、2.5 與 3.0 小時後血漿 中褪黑激素之濃度分別為 102.8 ± 24.3、 51.5 ± 13.0、 30.2 ± 7.1、22.2 ± 7.2、 20.4 ±.9.8、與 179.8 ± 8.1nM (平均值± SEM,n=8),其清除率相當快速,約 3 小時後 可完全清除血漿中褪黑激素;而此 SD 品系大白鼠之實驗動物模式將可廣泛應用在探討大白 鼠對褪黑激素抗氧化相關主題之研究上。 |
英文摘要 | Melatonin (5-methoxy-N-acetyltryptamine) plays a role in a number of distinct physiological functions. We have developed a convenient high performance liquid chromatography assay with electrochemical detection (HPLC/ECD) for the accurate determination of melatonin in biological samples. This assay involves direct addition of rat plasma to acetonitrile for simultaneous protein precipitation and melatonin extraction. The assay was validated by addition of melatonin to rat plasma with a recovery rate between 92 and 99%. The correlation coefficient of calibration curve was 1.000. The relative standard deviations for intraday and interday analyses were 1.5 ~ 2.2% and 3.5 ~ 5.0%, respectively. Melatonin clearance rate of biological samples were determined by this method. Melatonin (0.67 mg/kg) were given to Sprague Dawley rats by femoral vein injection. The melatonin concentrations were determined by HPLC/ECD at 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 hrs. The concentrations were reached the peak levels at 0.5-1.0 hrs and cleared after 3.0 hrs. The concentrations of melatonin wer 102.8 ± 24.3, 51.5 ± 13.0, 30.2 ± 7.1, 22.2. ± 7.2, 20.4 ± 9.8 and 17.9 ± 8.1 nM (mean ± S.E.M., n=8) at 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 hrs, respectively. This HPLC/ECD method can be useful in its application to biomedical studies of melatonin. |