查詢結果分析
相關文獻
- 核子醫學科之環境輻射背景評估
- Development of a Device for Immobilization of Head and Correlation of Functional-Anatomical Brain Images
- A SPECT Study of Patients with Gait Apraxia Without Evidence of Frontal Lobe Dysfunction
- 非一致性衰變校正鉈-201心肌灌注掃描對國人冠心病病灶偵測之研究--與心導管結果相比較
- Reconstruction-Based Estimation of the Scatter Component in Positron Emission Tomography
- An Inter-Iteration Parallel Algorithm for PET Image Reconstruction
- [fee6]Tc-Methylene Diphosphonate Planar Skull Bone Scan in Detecting Basal Skull Lesions in Nasopharyngeal Carcinoma
- Improved Diagnostic Performance of Thallium-201 Myocardial Perfusion Scintigraphy in Coronary Artery Disease: From Planar to Single Photon Emission Computed Tomography Imaging
- Single Photon Emission Computerized Tomography in Children with Developmental Language Disorder--A Preliminary Report
- PET/CT斷層掃描儀臨床應用
頁籤選單縮合
題名 | 核子醫學科之環境輻射背景評估=Evaluating Environmental Radiation Background among Nuclear Medicine Department |
---|---|
作者 | 張賴昇平; 陳健懿; 洪伶玟; 陳惠萍; Chang Lai, Sheng-pin; Chen, Chien-yi; Hung, Lin-wen; Chen, Hui-ping; |
期刊 | 中華放射線技術學雜誌 |
出版日期 | 20161200 |
卷期 | 40:4 2016.12[民105.12] |
頁次 | 頁243-249 |
分類號 | 414.93 |
語文 | chi |
關鍵詞 | 熱發光劑量計; 正子電腦斷層掃描; 電腦斷層掃描; 單光子電腦斷層掃描; 環境輻射; Thermoluminescent dosimeter; Positron emission tomography; Computed tomography; Single-photon emission computed tomography; Environmental radiation; |
中文摘要 | 針對林新醫院核子醫學科2010年成立的新的正子電腦斷層掃描/電腦斷層掃描(positron emission tomography/computed tomography, PET/CT)儀與單光子電腦斷層掃描(single-photon emission computed tomography, SPECT)儀,進行可能增加的環境輻射研究。本計畫使用準確性的熱發光劑量計(thermoluminescent dosimeter, TLD-100H),佈點於核子醫學科進行六個月的環境輻射背景測量。實驗結果顯示核子醫學科內的等候室、注射室以及PET/CT檢查室內輻射劑量有明顯的變化,而在科內地區的平均輻射劑量範圍由0.13±0.02至4.12±0.62 mSv/mo之間。再將科內分成四地區,t-test證明這些區域有顯著不同,佈點期間台中市其他地區的背景值為0.13±0.03至0.16±0.03 mSv/mo。這些實驗數據顯示在院內的工作人員,所接受到的輻射劑量值,是在合理可接受的限制內的,遠低於輻射工作人員的職業曝露限制以及ICRP 60所推薦的劑量限度。 |
英文摘要 | This study demonstrates a possible increase in environmental radiation background at the Nuclear Medicine Department (NMD) in Lin Shin Hospital, resulting from the new operated positron emission tomography/computed tomography (PET/CT) and single-photon emission computed tomography (SPECT) founded in 2010. Therefore, the environmental radiation dose rates may be higher than before. Environmental radiation backgrounds were evaluated by the accurate and sensitive thermoluminescent dosimeter (TLD-100H) among NMD during six month surveys. Measured results indicated that patient waiting rooms, injection rooms and PET/CT operation room, and staff working area had significantly different radiation dose rates. These averaged environmental radiation dose rates ranged from 0.13±0.02 to 4.12±0.62 mSv/mo among NMD. NMD areas were divided into four parts and t-test demonstrated environmental radiation doses were significantly different among these parts. Environmental radiation dose rates of Taichung City ranged from 0.13±0.03 to 0.16±0.03 mSv/mo. These preliminary data showed that the radiation doses of staffs are within the acceptable limits and far lower than ICRP 60 recommended. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。