查詢結果分析
相關文獻
- 極低體重早產兒周邊血壓與臍動脈血壓之相關性
- The Use of Prophylactic Intravenous Immunoglobulin Therapy in Very Low Birthweight Infants
- Staphylococcus capitis Bacteremia of Very Low Birth Weight Premature Infants at Neonatal Intensive Care Units: Clinical Significance and Antimicrobial Susceptibility
- Efffect of Erythromycin on Feeding Intolerance in Very Low Birth Weight Infants: A Preliminary Observation
- The Anesthetic Management of A Preterm Infant Weighing 500 Grams Undergoing Ligation of Patent Ductus Arteriosus--A Case Report
- Glucose and Insulin Infusion Versus Kayexalate for the Early Treatment of Non-oliguric Hyperkalemia in Very-Low-Birth-Weight Infants
- 極低體重早產兒肺出血之探討
- Intraventricular Hemorrhage, Periventricular Leukomalacia and Hypoglycemia in Very Low Birth Weight Infants: Relationship to Neurodevelopment at Two Years of Age
- Sepsis in the Very Low Birth Weight Infants in Taiwan
- 談日本1000公克以下極低體重早產兒7-9歲的追蹤成果
頁籤選單縮合
題名 | 極低體重早產兒周邊血壓與臍動脈血壓之相關性=Relationship between Peripheral Blood Pressure and Umbilical Arterial Blood Pressure in Premature Babies with Extremely Low Body Weight |
---|---|
作者 | 曾淑彬; 江志民; 葉淑惠; 徐旭香; 蘇紫蘋; Tseng, Shu-bin; Chiang, C. M.; Yeh, Shu-hui; Hsu, Hsu-hsiang; Su, Tzu-pin; |
期刊 | 秀傳醫學雜誌 |
出版日期 | 20120600 |
卷期 | 11:1/2 2012.06[民101.06] |
頁次 | 頁19-28 |
分類號 | 417.5171 |
語文 | chi |
關鍵詞 | 極低體重早產兒; 臍動脈血壓; 周邊血壓; Premature baby; Extremely low body weight; Umbilical arterial blood pressure; Peripheral blood pressure; |
中文摘要 | 極低體重早產兒為較不成熟發展階段的出生兒,對於周邊血壓的測量變異程度極大,多數依靠臍動脈導管來測量極低體重早產兒之血壓,但臍動脈導管易影響血循及血栓等合併症。因此,本研究目的為探討極低體重早產兒周邊與臍動脈血壓兩者間之相關性,研究方法以描述相關性研究設計,對象採方便取樣,收集南部某醫學中心新生兒加護病房,置放臍動脈導管的11位極低體重早產兒,測量工具為臍動脈導管及多功能生理監測器。測量出生後四天內的四肢及臍動脈的血壓,共測得77次血壓值。統計方法以SPSS version 15.0進行資料統計分析,結果發現極低體重早產兒周邊與臍動脈血壓有正相關,其中以右上肢之平均血壓與臍動脈血壓的相關性最高(Spearman rho = .74)。臍動脈之平均壓可以右上肢平均壓來推估,其公式為:臍動脈平均壓=10.35+0.73x右上肢平均壓。結論,建議在沒有臍動脈導管可以測量極低體重早產兒之直接血壓時,護理人員可測量右上肢之周邊血壓來推估臍動脈平均壓,並增加平均血壓值之紀錄來提供醫療處置之參考。 |
英文摘要 | The development of premature babies with extremely low body weight (ELBW) is immature. It is difficult to monitor the blood pressure of these babies accurately. Therefore, most physicians rely on umbilical arterial catheter insertion. However, umbilical arterial catheter can lead to complications, such as poor perfusion or necrosis. Research aim: The purpose of this study was to explore the relationship between peripheral blood pressure value and umbilical arterial blood pressure value in premature babies with extremely low body weight. Research method: A descriptive correlational research design with convenience sampling was used to conduct this study. Subjects: Participants were recruited from among premature babies with extremely low body weight who had umbilical arterial catheter performed upon being admitted to the neonatal intensive care unit at a medical center in southern Taiwan. Peripheral blood pressure values and umbilical arterial blood pressure values were taken 4 days after birth. A total of 77 blood pressure values from 11 patients were obtained. Measures: Hewlett Packard Omnicare CMS24 and a Kendall Umbilical artery catheter were used to measure blood pressure values. Statistics: The SPSS version 15.0 was used to analyze data. Results: The results indicate a positive correlation between the peripheral blood pressure of the four limbs and umbilical arterial blood pressure. The mean blood pressure of the right arm (Spearman rho = .74) showed the highest correlation with umbilical arterial blood pressure in comparison to the other limbs. Conclusion: From the results of this study, when an umbilical arterial catheter is unavailable, we suggest measuring the blood pressure in the right arm to estimate the umbilical mean blood pressure of premature babies with extremely low body weight as reasonable method for healthcare practitioners. |
本系統之摘要資訊系依該期刊論文摘要之資訊為主。