查詢結果分析
相關文獻
- Measurements of High Frequency Ultrasonic Backscattering from Blood--Frequencies Ranged from 5 to 42.5 MHz
- 臺北地區感染心絲蟲犬隻之血液生化學變化
- The Significance of Syphilis Serology Tests on Long-Term Hemodialysis Patients
- Watermelon Stomach--An Unusual Cause of Recurrent Upper Gastrointestinal Bleeding in a Uremic Patient Receiving Estrogen-Progesterone Therapy: Case Report
- 舉重選手重量訓練後血液生化值的變化
- The Effect of Coagulation Protection with Combination of Epsilon Aminocaproic Acid and Plasma Saver in Open-Heart Surgery
- Detection of Endogenous Digitalis-Like Immunoreactive Factors in Human Blood
- In Vitro Assessment of the Flow Fields in a Three-Dimensional Pulmonary Artery Model with Varying Degrees of Valvular Stenosis
- Serum Transferrin Receptor Concentration is Not Indicative of Erythropoietic Activity in Chronic Hemodialysis Patients with Poor Response to Recombinant Human Erythropoietin
- 飼糧中添加抗壞血酸對本省熱季產蛋雞生產性能及血液性狀之影響
頁籤選單縮合
題名 | Measurements of High Frequency Ultrasonic Backscattering from Blood--Frequencies Ranged from 5 to 42.5 MHz=血液的高頻率超音波逆散射測量--頻率範圍由5至42.5MHz |
---|---|
作者 | 王士豪; 廖峻德; 蔡富全; 蔡正倫; Wang, Shyh-hau; Liao, Jiunn-der; Tsai, Fu-chuan; Tsai, Cheng-lun; |
期刊 | Journal of Medical and Biological Engineering |
出版日期 | 20010600 |
卷期 | 21:2 2001.06[民90.06] |
頁次 | 頁105-110 |
分類號 | 414.7 |
語文 | eng |
關鍵詞 | 高頻超音波; 逆散射; 血液; High frequency ultrasound; Backscattering; Blood; |
中文摘要 | 當高頻率超音波被使用時,接收用換能器就可能解析樣本容積內每個散射子的形狀,使血液的超音波散射特性不同於過去使用頻率低於15MHz的測量結果。為此和日益增多的高頻超音波系統發展需要,懸浮於生理食鹽水與血漿的紅血球的超音波逆散射特性被探討,所使用的頻率是界於5到42.5MHz間,血液的血容比是界於5至35%。每個測量結果都被6%血容比的結果正規化,此步驟是採用先前發展出的新處理方法來消去換能器的聲束特性。5至30MHz測量的懸浮紅血球結果和以前用頻率低於15MHz與以球狀散射子的群集因子的理論結果非常吻合。而頻率高於30MHz的測量結果,除產生第一個逆散射波峰位於約13%血容比外,也產生第二個波峰約位於25%處;這是過去使用較低頻率的測量所未報導過的。到底此現象是因為高頻率超音波可較好的解析散射子的形狀或其他因素,至今仍不太清楚。全血和懸浮血球的超音波逆散射特徵不太一致,全血產生最大的逆散射位於血容比約在20到30%間,此現象可能是因為形成紅血球聚集導致紅血球的形狀與大小都被改變。 |
英文摘要 | The receiving transducer could better resolve the shape of each scatterer in the sample volume when the high frequency ultrasound is applied. As a result, scattering properties of blood would be different from those of previous measurements using frequencies lower than 15 MHz. For this reason and the increasing interest in developing high frequency ultrasound systems, ultrasonic backscattering properties of red cells suspended in saline and plasma were explored by measurements at frequencies between 5 and 42.5 MHz and hematocrits ranged from 3 to 35%. Measurements were analyzed by normalizing each result with that acquired from a low hematocrit at 6%. This procedure is to cancel out beam characteristics of the transducer adopted from a new approach that was previously proposed. Results obtained from red cell suspensions at frequencies ranged between 5 and 30 MHz were well consistent with those of previous measurements at frequencies lower than 15 MHz as well as the theoretical packing factor for a spherical scatterer. Measurements at frequencies higher than 30 MHz on the other hand demonstrated a second peak around 25% hematocrit in addition to the first peak near the 13%. Such finding was never reported for measurements at lower frequencies. Whether this is due to shape factor of scatterers corresponding to the applied high frequency remain unclear to date. Features of backscattering from whole blood however were not consistent with those measurements from red cell suspensions, the backscattering exhibited a maximum at a hematocrit between 20 and 30%. The modification of the shape and size of whole blood due to formation of red cell aggregation would account for this phenomenon. |